Table 1. Test Results for Good Cable (continued)
Results for coaxial cable.
Remote ID #3 detected.
Results for terminated coaxial cable. The tester
shows the total resistance of the cable and
terminator. Length cannot be measured on
terminated cable.
Table 2. Fault Results: Remote Identifier Optional
Short between wires 1 and 2.
The display shows the shorted wires and whether
the short is at the near end (NEAR-END) or far end
(FAR-END) of the cable.
For a short greater than 0 Ω, the displayed length
is greater than the actual distance to the short.
Short to the shield. For shielded cable (FTP) the
shield is shown as
The display shows the wire shorted to the shield
(wire 3 in this example).
H
.
-continued-