PanelView Plus and PanelView Plus Compact 400 and 600 Terminals
Startup Error Messages
When an error occurs, the terminal displays an error number with a text message. The word
ERROR! appears under the message in different languages.
ERROR! FEHLER! ERREUR! ERRORE!
Error #
Message
1
RAM Test
14
RAM Header
Check
20
Transfer Image
23
Download Task
24
CRC Check
25
Invalid Prod
Family
27
Decompress
System
30
Watchdog Test
31
Stuck Key
3a
Stuck Touch
40
EXE Check
Publication 2711P-IN002G-EN-P - November 2009
# Displayed Message
Description
RAM test failure.
OS firmware that is
downloading is not
compatible with
hardware.
Programming the
downloaded OS
firmware into Flash
failed.
OS firmware that is
downloading to the
terminal is too large.
Checksum of the OS
firmware failed.
OS firmware that is
downloading is not
compatible with
terminal.
Error decompressing
the OS firmware from
flash to RAM.
Watchdog test
failure.
Function key failure.
Touch screen failure.
System OS firmware
is missing or corrupt.
Recommended Corrective Action
Reset the terminal. If error persists, replace the
terminal.
Check that you are using the correct version and type
of firmware upgrade. Reset the terminal and upgrade
with the correct firmware version.
Reset the terminal and attempt the firmware upgrade
again. If error persists, replace the terminal.
Check that you are using the correct version and type
of firmware upgrade. Reset the terminal and upgrade
with the correct firmware version.
Reload the firmware. If error persists, replace the
terminal.
Check that you are using the correct version and type
of firmware upgrade. Reset the terminal and upgrade
with the correct firmware version.
Reload the firmware. If error persists, replace the
terminal.
Reload the firmware. If error persists, replace the
terminal.
Check that nothing is pressed against a key. Reset
the terminal without key presses. If error persists,
replace the terminal.
Check that nothing is pressed against the touch
screen. Reset the terminal without touch screen
presses. If error persists, replace the terminal.
Reload the firmware. If error persists, replace the
terminal.