Check the Display
If the terminal display is dim or unreadable:
• check the brightness setting. From terminal Configuration mode, choose Terminal
Settings>Display Intensity.
• check the contrast setting. From terminal Configuration mode, choose Terminal
Settings>Display Contrast.
• check the Screen Saver settings. The backlight may turn off or dim the display
unexpectedly. From terminal Configuration mode, choose Terminal
Settings>Display>Screen Saver.
Startup Information Messages
Startup information messages display in a specific sequence on the terminal screen during
startup and typically display for a few seconds. These messages do not require that you
perform any action.
Message # Message
30
Watchdog Test
1
RAM Test
2
Image Search
11
Downloading Image
20
Transfer Image
24
CRC Check
27
Decompress System
28
Starting System
29
System Check ###
29.1
System Check
PanelView Plus and PanelView Plus Compact 400 and 600 Terminals
Description
Tests the watchdog circuitry to verify system integrity.
Tests the RAM memory.
Checks for new OS firmware upgrade on the external compact flash
card and the serial port.
Transfers a new OS firmware upgrade to internal RAM. Message may
remain on screen for several minutes.
Programs the OS firmware just downloaded into RAM. Message may
remain on screen for several minutes.
Checks the integrity of the OS firmware.
Decompresses the compressed OS firmware into RAM.
Launches the operating system (OS).
Internal file system integrity check (### is percent progress indicator).
Internal file system check disabled. Contact technical support.