EV-VAR To Farm Hand Stage Master Wiring Connections ................9 Separating Circuits to Operate Different Equipment ..................10 Combining Circuits to Operate the Same Type of Equipment ............... 11 Replacement Parts ............................12 Part No. 4801-5315 Rev 1-15 Table of Contents Evolution Variable Output...
Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the location and installation of products manufactured or sold by GSI. Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 3 of 12...
The Evolution Variable Output is one of Hired-Hand's latest addition to the electronic controller product line. Evolution Variable Output (EV-VAR) is used to vary the speed of fans or to vary light luminosity. The Off or On switch setting overrides the main control system. To allow variable control of the EV-VAR output, connect EV- VAR to a Hired Hand Evolution 3000/3001 controller or to a Farm Hand Stage Master Controller with the EV-VAR switch set on VARIABLE.
5. Front Panel Features Evolution Variable Output (EV-VAR) is used to vary the speed of fans or to vary light luminosity. To control the EV-VAR output, connect EV-VAR to a Hired Hand Evolution 3000/3001 controller or to a Farm Hand Stage Master Controller. See wiring diagrams for proper connections.
The 20 Amp Fuse is easily accessible when replacement is required. WARNING Disconnect All Electrical Power Sources To Evolution 3000/3001 Controller Or Farm Hand Stage Master Controller Before Replacing Fuse! Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 6 of 12...
EV-VAR PCB 172 Board Layout and Connection Locations Evolution Variable Output PCB 172 Control Jumper Connections See Section 6.5. CONTROL JUMPERS Farm Hand Connections See Section 6.4. Evolution Connections See Section 6.3. Front Panel Switch Connector AC OUT Connections See Section 6.6.
7. Wiring Connections EV-VAR To Evolution 3000/3001 Wiring Connections To control the EV-VAR output using an Evolution 3000/3001 controller, connect EV-VAR using the wiring diagrams below for proper connections. Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 8 of 12...
EV-VAR To Farm Hand Stage Master Wiring Connections To control the EV-VAR output using a Farm Hand Stage Master controller, connect EV-VAR using the wiring diagrams below for proper connections. Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 9 of 12...
In some cases, you may want to operate a combination of lights and fans. The following is an example of how one would wire two circuits for lights and then two circuits for fans while integrated into the Evolution 3000. Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 10 of 12...
In some cases, you may want to operate all lights or all fans. The following is an example of how one would combine circuits one and three with circuits two and four for only one connection to the Evolution 3000. Part No. 4801-5315 Rev 1-15 Evolution Variable Output Page 11 of 12...