Curtain controller sprocket and chain drive (48 pages)
Summary of Contents for Cumberland 891-00516
Page 1
EDGE Models: 891-00516 Quick start 895-00692 Version 02 NOTE: For more complete information on the product, please refer to the manual on the USB key provided with your EDGE manual or go to the following web sites : http://www.automatedproduction.com/en/apmanuals.php http://www.cumberlandpoultry.com/sales-and-service/manuals.html...
Technical Specifications Table 1 EDGE Main Controller safety ratings Inputs: Supply Input : 24VDC, 15W Outputs: Alarm relay output: 24VDC/AC ; 1.5A MAX Operating Temperature 0 to 40°C (32 to 104°F) Storage Temperature -20 to 50°C (-4 to 122°F) Environment Type Indoor use only Pollution Degree Installation Category...
Page 4
Table 2 EDGE Main Controller — dimensions and weight (cont'd.) Bottom 250mm (10 inches) Hinge side 180mm (7 inches) Latch side 150mm (6 inches) EDGE 3-Slot Expansion Box - dimensions and weight Enclosure Height 660 mm (26 inches) dimensions Width 457 mm (18 inches) Depth 279 mm (11 inches)
Page 5
Table 3 6-Slot Expansion Box and 3-Slot Expansion Box ratings (cont'd.) 240Vac; 5A MAX Minimum load of 0.2A NO (Normally Opened) contact - DC load 24Vdc; 5A MAX. ( Current reading not available in DC). Minimum load of 0.2A NO (normally opened) contact - LED and CCFL loads 120/208/240Vac, 750W;...
Page 6
Table 3 6-Slot Expansion Box and 3-Slot Expansion Box ratings (cont'd.) Motor/inductive load 10,5 A MAX Minimum load of 0.2A Full Load amperage on the motor nameplate is not the maximum amp. When varying, the amperage might be higher. (Nb of Units = Max current rating divided by the max current of the fan ) LED and CCFL loads 120/208/240Vac;...
Page 7
Variable output Frequencies range : 40-70 Hz. module (SSR) cur- Accuracy of ±0.6A for AC load <20A in a normal environment. rent sensor Allowable loss of performance in a noisy environment: Accuracy of ±0.8A from initial reading with a load of 1% precision used for testing purpose Relay outputs with Accuracy of ±0.5A for AC load <20A in a normal environment.
Page 8
FV-0 Flame Rating (IEC 60695 or IEC 60707) IK rating (degree of mechanical protec- tion - impact, IEC 62262)
Page 9
Low voltage cable ratings Table 1 communication bus — communication cables Item Description Cable type Twisted and shielded Minimum gauge 1 mm2 (18 AWG) Maximum cable length (including cable extensions) 1200 meters (4000 feet) Certification and type CSA, CMG FT4 type, 18 AWG, 600 V, 75 °C (167 °F) UL, AWM or CM ttype, 18 AWG, 600 V, 75 °C (167 °F) Characteristic Impedance 120 Ω...
Page 10
*The recommended cable is AlphaWire 6451- 2 pairs: - 1 pair 18AWG twisted shielded for Communication; - 1 pair 15AWG twisted shielded for Power Table 3 Other Low voltage cables Item Description Twisted and shielded Cable type Minimum gauge 1 mm2 (18 AWG) Maximum sensor cable length 150 m (500 feet) •...
Page 11
Wiring diagram choice according to the equipment The following table helps you select the wiring diagram to refer to in order to connect the equipment you have. Equipment On/off On/off Variable Variable Variable Dual Inlet Inlet Inputs Output name failsafe 0-10 VDC with SSR with realy...
Page 12
NOTE: For more complete information on the product, please refer to the manual on the USB key provided with your EDGE manual or go to the following web sites : AP website: http://www.automatedproduction.com/en/apmanuals.php Cumberland website: http://www.cumberlandpoultry.com/sales-and-service/manuals.html...