Connect The Holding Brake; Figure 6-5 Sensor Module Mounted On The Terminal Box - Siemens 1PH818 Operating Instructions & Installation Instructions

Synchronous motor
Table of Contents

Advertisement

Cable outlet directions
The sensor module is mounted on the motor terminal box. The sensor module can be rotated
through approximately 235°. You can change the cable outlet directions by rotating the sensor
module, as shown in the diagram below.
NOTICE
Damage to the sensor module
You can damage the sensor module if you turn it with a pipe wrench, a hammer, or similar
tools.
Turn the sensor module by hand. The typical torque is approx. 4 ... 8 Nm.
Figure 6-5
NOTICE
Modifying the cable outlet direction
Changing the cable outlet direction by any improper means will damage the connecting
cables.
The permissible rotation range must not be exceeded. A maximum of ten changes to the
rotation angle of the Sensor Module are permissible within the rotation range.
6.4.4

Connect the holding brake

Information for electrically connecting the holding brake can be found in the operating
instructions supplied by the manufacturer in the (Page 139) appendix.
SIMOTICS M-1PH8 1PH818., 1PH822.
Operating Instructions 07/2016
Sensor Module
mounted on the terminal box
Electrical connection
6.4 Auxiliary circuits
79