Da-Lite Tensioned Advantage Deluxe Electrol Instruction Book page 7

Hide thumbs Also See for Tensioned Advantage Deluxe Electrol:
Table of Contents

Advertisement

Tensioned Advantage
120V Wiring Diagram
NOTE: Electrical connections on
left end of case.
Use provided knockouts for all
electrical connections. DO NOT
drill additional holes into screen
case or end cap.
Power Input
120VAC / 60HZ
220V Wiring Diagram
NOTE: Electrical connections on
left end of case.
Use provided knockouts for all
electrical connections. DO NOT
drill additional holes into screen
case or end cap.
Power Input
220VAC / 50HZ
Deluxe Electrol
®
Front of
UP
Wall
STOP
Switch
DOWN
Optional RF or IR
(Down)
Remote Connector
Not Used
AUX EYE
Black
(Hot)
Green
(Ground)
Front of
Wall
Switch
Optional RF or IR
Remote Connector
Not Used
Brown
(Hot)
Green/Yellow
(Ground)
Instructions For Standard Control
®
Back of
Wall
Switch
Red
(Up)
Black
White
(Common)
White
(Common)
Dual Motor Control Board
Door
Switch
Back of
UP
Wall
STOP
Switch
DOWN
Red
(Up)
Black
(Down)
White
(Common)
AUX EYE
Blue
(Common)
Dual Motor Control Board
Door
Switch
NOTE: 20-24AWG Wire Recommended
For Connecting Wall Switch to the Dual
Motor Controller
White
(Common)
Black
(Down)
Red
(Up)
Green
(Ground)
White
(Common)
Black
Green
(Down)
(Ground)
Red
(Up)
NOTE: 20-24AWG Wire Recommended
For Connecting Wall Switch to the Dual
Motor Controller
Blue
(Common)
Brown
(Down)
Black
(Up)
Green/Yellow
(Ground)
Blue
(Common)
Brown
Green/Yellow
(Down)
(Ground)
Black
(Up)
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Screen Motor
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Door Motor
Blue (Common)
Brown (Down)
Black (Up)
Green/Yellow (Ground)
Screen Motor
Blue (Common)
Brown (Down)
Black (Up)
Green/Yellow (Ground)
Door Motor
7