Section 1
General Information
Block Title
Parameter
OUTPUT
OPTO OUTPUT
#1 – #4
Zero SPD Set PT
At Speed Band
Set Speed
MN718
Table 4-2 Level 1 Parameter Block Definitions
Description
Four optically isolated digital outputs that have two operating states, logical High or Low.
Each output may be configured to any of the following conditions:
Condition
Ready -
Zero Speed -
At Speed -
At Set Speed -
Overload -
Keypad Control -
Fault -
Following ERR -
Motor Direction -
Drive On -
CMD Direction -
AT Position -
Over Temp Warn - Active when control heat sink is within 3 C of Int Overtemp.
Process Error -
Drive Run -
Sets the speed at which the Zero Speed opto output becomes active (turns on). When the
speed is less than the ZERO SPD SET PT, the Opto Output becomes active. This is use-
ful when a motor brake is to interlock operation with a motor.
The At Speed Band serves two Opto Output Conditions and the Level 2 Protection block
Following Error:
Sets the speed range in RPM at which the At Speed opto output turns on and remains
active within the range.
Sets the Following Error Tolerance Band for the Level 1 OUTPUT, Opto Output condition
Following ERR. The opto output is active if the motor speed is outside this band.
Sets the no fault operating speed range of the drive. This value is used by the Level 2
Protection block, Following Error parameter (if it is set to ON). If the drive speed falls
out of this band, the Level 2 Protection block, Following Error parameter will shut
down the drive (if it is set to ON).
Sets the speed that the AT Set Speed opto output becomes active (turns on). When the
speed is greater than the Level 1 Output SET SPEED parameter, the Opto Output
becomes active. This is useful when another machine must not start or stop until the
motor exceeds a predetermined speed.
- Continued
Description
Active when power is applied and no faults are present.
Active when output frequency to motor is below the value of the
Level 1 Output "Zero SPD Set Pt" parameter.
Active when output speed is within the speed range defined by
the Level 1 Output "At Speed Band" parameter.
Active when output speed is at or above the Level 1 Output
"Set Speed" parameter.
A normally closed contact that is active (opens) during an
Overload fault caused by a time out when output current is
greater than Rated Current.
Active when control is in Local keypad control.
Active when a fault condition is present.
Active when the motor speed is outside the user specified
tolerance band defined by the At Speed Band parameter.
Active High when REV direction command received. Active Low
when FWD direction command received.
Active when control is "Ready" (has reached excitation level and
capable of producing torque).
Active at all times. Logical output state indicates Forward or
Reverse direction.
Active during a positioning command when control is within the
position band parameter tolerance.
Active when process feedback signal is outside the range
specified by the Level 2 Process Control block, AT Setpoint
Band parameter. Turns off when process feedback error is
eliminated.
Active when drive is Ready, Enabled, Speed or Torque command
received with FWD/REV direction issued.
Programming & Operation 4-13