Reset Parameters To Factory Settings - Baldor 18H Series Installation & Operating Manual

Vector drive, ac flux vector control
Table of Contents

Advertisement

Section 1
General Information
Program Mode Continued

Reset Parameters to Factory Settings

Action
Apply Power
Press PROG key
Press Y or
key
Press ENTER key
Press Y or
key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press Y or
key
Press ENTER key
4-8 Programming & Operation
Sometimes it is necessary to restore the parameter values to the factory settings. Follow
this procedure to do so. Be sure to change the Level 2 Motor Data block "Motor Rated
Amps" to the correct value after this procedure (restored factory setting is 999).
Note: All specific application parameters already programmed will be lost when
resetting the control to factory settings.
Note: After factory settings are restored, the drive must be auto tuned.
Description
Keypad Display shows this
opening message.
If no faults and programmed for
LOCAL operation.
Enter program mode.
Scroll to Level 2 Blocks.
Select Level 2 Blocks.
Scroll to the Miscellaneous block.
Select Miscellaneous block.
Scroll to Factory Settings
parameter.
Access Factory Settings
parameter.
Scroll to YES, to choose original
factory settings.
Restores factory settings.
Scroll to menu exit.
Scroll to Programming exit.
Return to display mode.
Display
Logo display for 5 seconds.
Display mode. Stop LED on.
V
represents blinking cursor.
"Loading Presets" is first message
"Operation Done" is next
"No" is displayed last.
Exit Level 2 blocks.
Exit Programming mode and
return to Display mode.
Display mode. Stop LED on.
Comments
MN718

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents