Section 1
General Information
Other Analog Input:
Full Scale Range
Resolution
Update Rate
Analog Outputs:
Analog Outputs
Full Scale Range
Source Current
Resolution
Update Rate
Digital Inputs:
Opto-isolated Logic Inputs
Rated Voltage
Input Impedance
Leakage Current
Update Rate
Digital Outputs:
Opto-isolated Logic Outputs
ON Current Sink
ON Voltage Drop
Update Rate
Maximum Voltage
Diagnostic Indications:
Current Sense Fault
Ground Fault
Instantaneous Over Current
Overload
Line Power Loss
Microprocessor Failure
Over temperature (Motor or Control)
Over speed
Note: All specifications are subject to change without notice.
MN718
0 - 10 VDC
9 bits + sign
500 s
2 Assignable
0 - 5 VDC
1 mA maximum
8 bits
2.0 msec
9 Assignable
10 - 30 VDC (closed contacts std)
6.8 K Ohms
10 A maximum
16 msec
4 Assignable
50 mA Max
2 VDC Max
33 msec
30 VDC
Regeneration (db) Overload
Soft Start Fault
Under Voltage
Ready
Parameter Loss
Overload
Overvoltage
Torque Proving
Following Error
Encoder Loss
Logic Power Fault
Specifications, Ratings & Dimensions 7-3