Premier Mounts VPM Installation Instructions Manual

Premier Mounts VPM Installation Instructions Manual

Vesa pole mount
Hide thumbs Also See for VPM:

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
VPM
VESA Pole Mount
NORTH AMERICA
EUROPE
1321 S. State College Boulevard
Unit 3, The Moorings Business Park,
Fullerton, CA 92831 USA
Channel Way, Longford,
USA and Canada
Coventry, CV6 6RH, UK
Phone: 1.800.368.9700
Phone: +44 (0)24 7664 4105
Fax: 1.800.832.4888
Fax: +44 (0)24 7664 4165
Other Locations
Phone: (001).714.632.7100
Fax: (001).714.632.1044
9531-057-001-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VPM and is the answer not in the manual?

Questions and answers

Summary of Contents for Premier Mounts VPM

  • Page 1 INSTALLATION INSTRUCTIONS VESA Pole Mount NORTH AMERICA EUROPE 1321 S. State College Boulevard Unit 3, The Moorings Business Park, Fullerton, CA 92831 USA Channel Way, Longford, USA and Canada Coventry, CV6 6RH, UK Phone: 1.800.368.9700 Phone: +44 (0)24 7664 4105 Fax: 1.800.832.4888 Fax: +44 (0)24 7664 4165 Other Locations...
  • Page 2: Table Of Contents

    PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY. PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY...
  • Page 3: Installation Tools

    Installation Tools The following tool may be required depending on your installation. Phillips Tip Screwdriver Parts List Make sure none of the Premier Mounts parts are missing and/or damaged before beginning installation. If there are, stop the installation and call Premier Mounts at (800) 368-9700. VPM Components Fixed Tilt Adapter - Left Fixed Tilt Adapter - Right VESA Pole Mount (Qty 1) Adapter Plate (Qty 1) (Qty 1) (Qty 1) Universal Spacer Thread Depth (Qty 8) M5 Allen Wrench (Qty 1) Indicator (Qty 1) Installation Instructions Page 3 Visit the Premier Mounts website at www.mounts.com...
  • Page 4 (Qty 4) M6 x 10mm Pan Combo Screw (Qty 4) M6 x 16mm Pan Combo Screw (Qty 4) M8 x 12mm Pan Combo Screw (Qty 4) M8 x 16mm Pan Combo Screw (Qty 4) Page 4 Installation Instructions Visit the Premier Mounts website at www.mounts.com...
  • Page 5: Features

    The VPM fits 1-1/2” and 2” tubing, as well as Premier Mounts’ own elliptical tubing, for carts, stands and ceiling poles. The mount’s unique collar clasp design allows you to combine VPMs on a pole for back-to-back flat-panel installations. The VPM also includes both traditional screws and Lock-It™ security hardware for every installation scenario. Adjustable Tension Your flat panel stays at the Fits Many Pipes angle you choose even The collar clasp can when using a heavy display be adjusted to fit 1-1/2” by tightening the integrated and 2” tubing, as well set screws. as Premier Mounts’ own elliptical tubing. Stylish Design Sleek and unobtrusive, yet sturdy. Radial Glide Technology™ 360° rotation and 12° of pivot allows for superior viewing of your flat-panel. Installation Instructions Page 5 Visit the Premier Mounts website at www.mounts.com...
  • Page 6: Opening The Collar Clasp

    Adapter Plate the 100 x 100mm pattern of the adapter plate (see page 14). If No, go to the “Selecting the Mounting Hardware” section. Do not overtighten the mounting hardware. You can also attach the fixed tilt adapters upside down, i.e., for an upward tilt on a floor stage monitor stand. M4 x 10mm or M4 x 5mm screw Proceed to the “Selecting the Mounting Hardware” section. Page 6 Installation Instructions Visit the Premier Mounts website at www.mounts.com...
  • Page 7: Selecting The Mounting Hardware

    Depth Plus 1/8” Allowance or Toothpick or Toothpick Mark Mark Universal Spacer Installation (Optional) If your flat-panel has uneven mounting points, or recessed mounting points, please use the provided universal spacers. The universal spacer may be stacked six (1) high. It will fit M4, M5, M6 and M8 screws sizes. The universal spacers must be placed between the attachment head/adapter plate and the flat-panel. The universal spacers must be stacked in the direction shown to the right. Proceed to the “Installing the Adapter Plate (Optional)” section. Installation Instructions Page 7 Visit the Premier Mounts website at www.mounts.com...
  • Page 8: Installing The Adapter Plate (Optional)

    If 75 x 75mm or 200 x 200mm, proceed to the 75 x 75mm or 200 x 200mm section. • If 200 x 100mm, go to the 200 x 100mm section on page 9. • If 100 x 100mm, go to the “Attaching the Flat-Panel to the VPM Mount” section on page 10. The adapter plate has a 100mm x 100mm VESA pattern, but that is only for attaching the plate to the attachment head of the VPM. 75 x 75mm or 200 x 200mm If you have a recessed mounting pattern, use Optional fixed tilt adapters not shown.
  • Page 9 200mm x 100mm Mounting Pattern Installation If using a 200 x 100mm mounting pattern to attach the VPM to your-flat panel, you must use six (6) M4 flat head screws. Using pan combo screws for the 200mm x 100mm VESA plate may damage your flat panel. Proceed to the “Attaching the Flat-Panel to the VPM Mount” section. Flat- Universal Adapter M4 Flat Panel Spacer Plate Head Screw Figure 1 Figure 2 Installation Instructions Page 9 Visit the Premier Mounts website at www.mounts.com...
  • Page 10: Attaching The Flat-Panel To The Vpm Mount

    Attaching the Flat-Panel to the VPM Mount Choose one of the following options. Drawings not to scale. Optional fixed tilt adapters not shown. No Fixed Tilt Adapters Are you attaching the VPM directly to the flat-panel, or are you using an adapter plate? Flat- Panel • If directly to the flat-panel, insert four (4) M4 x 10mm screws through the VPM -200 attachment head and 100 x 100mm pattern of the flat-panel (see page 14) (Figure 1). • If using an adapter plate, insert four (4) M4 x 5mm screws through the VPM attachment head and 100 x 100mm pattern of the adapter plate (see page 14) (Figure 1).
  • Page 11: Attaching The Vpm Mount To A Pole

    Attaching the VPM Mount to a Pole Drawings not to scale. Re-insert the M8 x 40mm hex screws or insert M8 x 40mm Mounting hardware not shown. security screws into the two halves of the VPM to clasp them around the pole at the desired position (Figure 1). At least two qualified people are needed to attach the flat-panel and VPM to a pole. If you are using a 2” pipe, replace the M8 x 40mm hex screws with M8 x 60mm security screws (Figure 2). Proceed to the “Adjusting the VPM Mount Tension” section. Caution: Front plate of VPM Tighten both screws...
  • Page 12: Adjusting The Vpm Mount Tension

    Adjusting the VPM Mount Tension Your VPM ships from the factory pre-tensioned. However, you can fine-tune adjust the amount of pressure required to move the attachment head of the VPM. Use the enclosed Allen wrench to adjust the tension by loosening or tightening the M10 set screws on each side of the VPM. Do not overtighten or remove the set screws. M10 Set Screw Installing Multiple VPMs (Optional) You can attach multiple VPM mounts to a pole, such as for back-to-back flat-panel installations. Page 12 Installation Instructions Visit the Premier Mounts website at www.mounts.com...
  • Page 13: Technical Specifications

    2.89 3.94 73.50 12° 4.79 3.94 121.56 12° Ø .18 4.56 4.50 115.87 10° Attachment Head Mounting Pattern A: 100 x 100mm VESA pattern Adapter Plate Mounting Patterns B. 200 x 100mm VESA pattern (M4 Phillips flat head screws only) C. 200 x 200mm VESA pattern If an M4 or M5 is to be used, a M4 or M5 washer must also be used. D. 100 x 100mm VESA pattern E. 75 x 75mm VESA pattern Installation Instructions Page 13 Visit the Premier Mounts website at www.mounts.com...
  • Page 14: Warranty

    What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will be shipped to you at no charge, but you must pay any labor costs.

This manual is also suitable for:

Vpm-100

Table of Contents