Minimum Safety Distances; Flueway - Piazzetta P962 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

1.8 MINIMUM SAFETY DISTANCES - Fig. 16 / 18
First of all decide the exact position for installation of the stove.
Check the minimum safe distances from heat sensitive or inflammable
materials, from load bearing and other walls and also from wooden
elements, furniture, etc.
In the case of flooring that is heat sensitive or inflammable the floor
should be protected with non-combustible insulating material, e.g.
sheets of steel plate, marble, tiles, etc.
The minimum distances are:
A
20 cm from the wall behind the stove
B
20 cm from the side wall
C
80 cm in the heat radiation area and from the hot air fan
D
50 cm floor proection
E
30 cm (measured from the internal corner of the door opening)
Connection to the flue must respect the 40 cm minimum safety
distance from heat-sensitive structural components or inflammable
materials (wood panelling, beams or ceilings, etc).
Keep away from the stove any combustible product such as
wooden furniture, curtains, carpets, combustible liquids, etc.
when it is lit /working (minimum distance 80 cm).
It is advisable to leave more than the indicated 20 cm free at
the side of the stove to facilitate any maintenance on the
appliance.
1.9 FLUEWAY - Fig. 19 - 20
The pellet stove is not the same as other stoves. It has a forced draught of flue gas by a fan, which keeps the firebox in a vacuum and the
entire flueway slightly pressurised. For this reason the flue must be completely airtight and correctly installed to ensure both trouble-free
operation and user safety.
- The flueway must be made by specialised personnel or firms, as outlined below.
- The flue must be installed in such a way as to guarantee that periodic cleaning can be carried out without dismantling any parts whatsoever.
- Pipes should always be sealed with silicone (not cement-based sealants) or specially adapted gaskets/seals, which retain their strength and
elasticity at high temperatures (250°C), and should be fixed with 3.9 mm ø self-tapping screws.
Do not install dampers or valves that could block the passage of flue gas.
Do not connect to a flueway into which other appliances (boilers, extractor hoods, etc.) discharge fumes or vapours.
All manuals and user guides at all-guides.com
Fig. 16
Parete posteriore
Rear wall
STUFA
B
E
D
Protezione pavimento
Floor protection
Zona radiante dell'apertura
Heat radiation area
del focolare
Fig. 17
DT2030335-00
DT2010536-02
A
B
STOVE
E
C
DT2031515-00
Fig. 18
DT2030336-00
DT2010229-04
GENERAL RULES