Sensor
Connected to the rear of the stove it constantly
monitors the temperature in the stove's
immediate environs to ensure its operation in
complete safety.
If the sensor detaches itself momentarily and/or
accidentally from its position, the problem does
not require the immediate shutdown of the stove,
Room sensor
which will continue to function normally at the
chosen power level.
The problem will be indicated on the display by
the readout "ton".
- Restore the sensor to its proper position.
- If the temperature display has been activated
this will once again be shown.

6.13 OPENING THE DOOR

During operation the door must remain closed. It is to be opened only when the stove has been shut down and cooled for the carrying out of
maintenance.
6.14 HUMIDIFIER FOR STOVE P962 - Fig. 61
A humidifier tank is a standard part of the stove and is fitted inside
the stove at the top under the grille in front of the pellet hopper. Use
the spray bottle provided in the kit to fill the tank with water,
inserting the nozzle into the relative hole made in the grille.
When filling the humidifier tank, take great care not to
overfill otherwise damage could be caused to the electrical
parts.

6.15 DISPOSAL OF ASHES

Ash from natural (non-treated) wood burned in stoves or open fireplaces is composed mainly of calcium, silicon, potassium and
magnesium oxides. The ashes can therefore be used as a fertiliser for plants or in the garden, albeit not exceeding 2.6 kg per 10 m
annually.
The ashes should be placed in a metal container with a sealed cover. The sealed container should be placed on a non-
combustible surface at a safe distance from combustible materials until the cinders have been completely extinguished.
Only when they have been fully extinguished can the ashes be thrown away with organic waste, assuming that nails or other
non-organic material are not present.
All manuals and user guides at all-guides.com
ROOM TEMPERATURE SENSOR
Description
WHEN ACTIVATED
WHAT TO DO
!
!
L E V E L
1 2 : 0 0 t o n
1
Fig. 61
Display
P 2
DT2040055-03
DT2010087-04
DT2010993-00
DT2031448-00
DT2010049-04
USE
2
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P950P955P956

Table of Contents