5.2 ELECTRICAL CONNECTION AND THE ROOM SENSOR
CONNECTION - Fig. 41 / 43
• The stove comes with a power cable which must be connected to
a 230v/50Hz (230V/60Hz only for Japan) supply. Connection to
the rear of the stove is shown in fig. 41.
• The power rating is indicated in the paragraph "TECHNICAL
DATA" in this booklet.
• According to law the installation must be earthed and include a
residual current circuit breaker.
• Ensure that in its normal position the power cable does not come
into contact with any heated parts.
Ensure that the electrical socket is accessible also after
installation of the stove.
• When installing the stove, it is necessary to connect the room
sensor (provided) in the correct socket (fig. 42). The sensor can
be positioned as shown in fig. 42, otherwise remove the band and
uncoil the lead and then place the sensor in a spot where a more
accurate room temperature reading can be obtained.
5.3 INSTALLING THE EXTERNAL THERMOSTAT - Fig. 41 - 44 / 46
• The appliance is designed for connection to an external room
thermostat. To connect the thermostat use a 2x0.5 mm
with a PG7 cable gland to be inserted in the relative hole in the rear panel
(fig. 41). Only authorised personnel should carry out this operation.
Installation can be carried out with any type of room thermostat
but requires a PG7 cable gland similar to that shown in fig. 44. To
connect the room thermostat to the electronic board, refer to the
wiring diagram.
Proceed as follows for installation:
• Remove the protective panel from the electronic board and then remove the
rear panel (fig. 45).
• Insert the thermostat cable through the PG7 gland and then insert the gland
in the hole in the rear panel (fig. 46).
• Connect the room thermostat cable terminal to the 2-pin terminal of the
electronic board (fig. 45).
• Refit the rear panel, ensuring that the cable inside the stove cannot come
into contact with hot or moving parts.
• Refit the protective panel over the electronic board.
20
INSTALLATION
All manuals and user guides at all-guides.com
COLLEGAMENTO ELETTRICO P962
DT2031443
2
cable secured
COLLEGAMENTO SONDA AMBIENTE P962
DT2031444
1
Fig. 41
1 External socket for connection of room sensor.
2 Socket for power lead.
3 External pressure pipe tap.
4 Hole for inserting cable gland PG7 for connection of external thermostat.
5 Room sensor connection.
6 Power cable connection.
Fig. 42
5
DT2031444-00
Fig. 44
1
2
COLLEGAMENTO CAVO DI ALIMENTAZIONE P962
DT2031445
1 Thermostat.
2 Electronic board 2-pin terminal.
Fig. 45
Fig. 46
DT2010146-00
1
2
3
4
DT2031443-00
Fig. 43
DT2031445-00
DT2010997-00
4
3
DT2030076-00
3 Cable clamp.
4 Thermostat cable terminal.
DT2031446-00
1
DT2031447-00
6