Modifying The Transmission Unit; How The Multifuoco System Works - Piazzetta P962 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

6.10 MODIFYING THE TRASMISSION UNIT
Should two pellet stoves of the same model be installed close to each other and the remote control beam activates both simultaneously, it is
possible to modify the transmission unit when the stove has been shut down by taking the following steps:
Function
Open the flap and press the SET and OPT keys
simultaneously. Using the SELECT MENU
Select UNIT function
choose one of the eight transmission units (0÷7).
Standard setting on pellet stoves is 0.
Disconnect the power cable. Reconnect it and
within five seconds press the ON/OFF key. Two
Restart stove
display pages will appear in sequence while the
remote control will return to the initial display.

6.11 HOW THE MULTIFUOCO SYSTEM WORKS

The pellet stove with 'Multifuoco' system is equipped with a fan for the diffusion of hot air. This facility allows multiple solutions for the diffusion
of channelled hot air, allowing the user freedom of choice as regards the number of adjoining rooms which can be heated.
The workings of the products 'Multifuoco' system will be be explained in general and conceptual terms below.
In order to adjust the action of the fan to suit the chosen redirection plan, a number of 'Multifuoco' settings have been preprogrammed: M1, M2,
M3, M4. Once the 'Multifuoco' setting has been chosen the user can then choose a greater or lesser quantity of heat by choosing one of the
stove's five power settings.
There is a greater volume of air transferred by the fan rising from levels M1 to M4. Similarly, there is a greater quantity of hot air being produced
by the stove rising from level P1 to level P5.
It is at the user's discretion, based on the experience he or she accumulates through acquaintance with the product in use, which of the 'Multifuoco'
settings and which power level to choose. These choices will be based on the stove's location, the room temperature at the chosen startup time
and of course on the desired room temperature.
For each of the solutions described in section 'Multifuoco' system a specific Multifuoco fan setting has been preprogrammed - M1, M2, M3, M4
- in order to adapt the rate of heat transferral to the chosen redirecting solution.
• If opting for Solution 1, it is best to use the control panel to select the corresponding setting M1. This setting will automatically adjust the fan speeds to the chosen
solution and will work with all FIVE of the stove's power settings.
• If opting for Solution 2, a greater transferral of heat will be required, in which case it would be best to select setting M2.
• Finally, if opting for Solution 3 and Solution 4, a yet greater transferral of heat will be required, in which case it would be best to select setting M3 or M4.
Before choosing the desired Multifuoco setting, start the stove up and wait until it is operating normally.
All manuals and user guides at all-guides.com
SELECT UNIT
Action
MENU
SET
ESC
OPT
!
S E L E C T
key
U N I T
!
S E A R C H
F I E L D
!
!
U N I T
L O A D E D
1
DT2010248-04
Display
0
0
0
DT2040072-03
DT2010231-03
USE
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P950P955P956

Table of Contents