6.12 SAFETY DEVICES

During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures.
Remember to maintain the safety distances indicated previously.
Be careful, take all due precautions and always comply with the instructions.
If during operation smoke leaks from any part of the stove or the flue, shut the stove down immediately and ventilate the room. When the stove
has cooled, check for the cause of the leak and if necessary call in specialist personnel.
The stove is fitted with several safety devices to guarantee safe operation.
The safety devices are fitted to eliminate the risk of injury to people and pets and damage to property. Tampering or work carried
out by unauthorised personnel can jeopardise this function.
Possible warnings of problems
Simple operating problems can usually be resolved with the help of the following pages.
Sensor
Connected to the flue gas outlet, its function is to
control the vacuum inside the outlet duct so that the
stove can be used in all safety.
If correct operating conditions in the flue gas outlet
change (incorrect installation, blockages or obstructions
in the flue, poor maintenance, unfavourable weather
conditions such as persistent wind, etc.) the pressure
switch cuts off the power supply to the fuel-loading
auger, thereby stopping the supply of pellets to the grate
and starting the stove shutdown process.
- The readout "ALF 1" appears in the STOVE STATUS
mode.
Pressure switch
- The readout "SMOKE SAFETY " appears on the display.
"ALF 1"
- After approx. 60 seconds the alarm sounds (if
activated).
- Shut down the stove by holding the ON/OFF key
down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any pellets
remaining in the grate has stopped.
- Wait until the stove has cooled down, then check for
and remove whatever has caused the safety device
to be triggered. Finally, after having cleaned the grate
restart the stove by pressing the ON/OFF key.
Its function is to check correct operation of the pressure
switch so that the stove can be used in all safety.
It activates during the "START" stage of the stove (see
"STARTING THE STOVE" table).
If an anomaly is detected in the pressure switch, the
readout "ALF 2" appears in the STOVE STATUS mode.
Pressure switch
The readout "SMOKE SAFETY" appears on the display.
"ALF 2"
After approx. 60 seconds the alarm sounds (if activated).
- Shut down the stove by holding the ON/OFF key down for
several seconds.
- The alarm stops.
- Call the After-Sales Service Centre.
40
USE
All manuals and user guides at all-guides.com
SMOKE CHAMBER PRESSURE
Description
WHEN ACTIVATED
WHAT TO DO
WHEN ACTIVATED
WHAT TO DO
DT2010994-00
Display
!
!
!
S A F E T Y
S M O K E
1
!
!
!
S A F E T Y
S M O K E
1
DT2040095-00