Absolute Register Address Description
30058/40058
Peak Starting Current
30059/40059
Last Starting Duration
30060/40060
Hottest Stator RTD Temperature
30061/40061
Hottest Bearing RTD Temperature
30062/40062
Hottest Other RTD Temperature
30063/40063
RTD 1 Temperature
30064/40064
RTD 2 Temperature
30065/30065
RTD 3 Temperature
30066/40066
RTD 4 Temperature
30067/40067
RTD 5 Temperature
30068/40068
RTD 6 Temperature
30069/40069
RTD 7 Temperature
30070/40070
RTD 8 Temperature
30071/40071
RTD 9 Temperature
30072/40072
RTD 10 Temperature
30073/40073
RTD 11 Temperature
30074/40074
RTD 12 Temperature
30075/40075
RTD 13 Temperature
30076/40076
RTD 14 Temperature
30077/40077
RTD 15 Temperature
30078/40078
RTD 16 Temperature
30079/40079
RTDs Enabled
30080/40080
RTDs Assigned as Stator
30081/40081
RTDs Assigned as Bearing
30082/40082
RTDs Assigned as Other
30083/40083
RTDs with Open Leads
30084/40084
RTDs with Shorted Leads
30085/40085
Remaining Lockout Time
30086/40086
Date/Time (lower 16 bits)
30087/40087
Date/Time (upper 16 bits)
30101/40101
Motor FLA
30102/40102
Motor Service Factor
30103/40103
Independent Start/Run Motor Overloads
30104/40104
Motor Overload Running Enable
APPENDIX F - MODBUS REGISTER MAP
Range
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
0 - 200
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD is enabled.
Bit 0 represents RTD 1. Bit 15 represents
RTD 16.
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD is assigned to
the stator group.
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD is assigned to
the bearing group.
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD is assigned to
the other group.
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD has an open
lead.
Bit Mask:
Each of the sixteen (16) bits represents an
RTD. A 1 indicates the RTD has shorted
leads.
(in 32-bit unsigned integer format)
1 – 6400
100 – 199
0:
Disabled
1:
Enabled
0:
Disabled
1:
Enabled
Units
A
rms
0.1 Sec
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
–
–
–
–
–
–
Sec
Sec
A
rms
0.01
–
–
187
Need help?
Do you have a question about the RediStart EXEXMVRMX3 Series and is the answer not in the manual?