Summary of Contents for Festo CMGA-E1

  • Page 1 Extension module CMGA-E1 Description Installation manual Extension module inputs/outputs 8037553 1404a...
  • Page 2 Necessary or useful accessories Information on environmentally sound usage Text designations: • Activities which may be carried out in any sequence. 1. Activities which should be carried out in the specified sequence. – General lists Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 3: Table Of Contents

    CMGA-E1 Table of contents – CMGA-E1 Important notes ............
  • Page 4: Important Notes

    The warranty and safety certifications are null and void if the modules have been manipulated. The CMGA can be operated in a temperature range between 0° and 50 °C. Make sure that this temper- ature range is not exceeded. Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 5: Modification Of An Installation

    Commissioning or modification of an installation of the CMGA can only be performed by qualified per- sonnel! Contact the company that produced the safety-relevant test report. Changing the configuration can cause the module to lose its safety function. Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 6: Commissioning

    CMGA-E1 Commissioning The CMGA-E1 is an input/output extension module that can only be used in combination with a CMGA basic module (i.e. CMGA-B1-M0-L0-A0, CMGA-B1-M1-L1-A0 or CMGA-B1-M2-L2-A0). It is connected to the basic module via the backwall bus. CMGA-B1-M2-L2-A0 CMGA-E1 CMGA-E1-CO Fig.
  • Page 7 Digital input 07 (I1.7) X23:4 IN08 Digital input 08 (I1.8) X24:1 IN09 Digital input 09 (I1.9) X24:2 IN10 Digital input 10 (I1.10) X24:3 IN11 Digital input 11 (I1.11) X24:4 IN12 Digital input 12 (I1.12) Tab. 1 Connections Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 8: Configuration

    Fig. 5 CMGA-E1 In this window, write the serial number of the CMGA-E1 (see rating plate) into the field “Device 1”. The value of the input field “Device 2” must be different from “Device 1” and must not be zero.
  • Page 9 CMGA-E1 Fig. 6 Device configuration Configure IO01 as input Configure IO02 as output Fig. 7 Example Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 10: Leds Cmga-E1

    Only the operating status 4 = RUN makes it possible to operate the machine or system. Only then are all configured safety functions active. If the CMGA is in the mode “Alarm” = A or in the mode “Failure” = F, all safety-relevant outputs are deactivated. Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 11: Error Types Of The Cmga

    If an alarm or fatal error occurs more frequently, contact the company that installed the machine or system. All error codes of the CMGA basic module, including the one from the CMGA-E1, are shown in the dis- play of the basic unit.
  • Page 12 CMGA-E1 CMGA-E1 specific error codes that are not listed in the CMGA installation instructions Alarm code A 2101 / A 2101 Description Error in transmission telegram, basic unit Cause Basic unit does not receive an answer from CMGA-E1 Remedy Check installation between basic unit and CMGA-E1...
  • Page 13 CMGA-E1 CMGA-E1 specific error codes that are not listed in the CMGA installation instructions Fatal error code F 3829 Description Status of the output EAA1.5 is incorrect Remedy Check the output circuit (short circuit) Check the configuration (input or output)
  • Page 14: Change / Handling Changes To The Modules Or Installation

    9. Switch on the supply voltage. Note: Plug-in connections of the CMGA module must not be disconnected or reconnected when powered. There is a danger of sensor damage, particularly with connected position or speed sensors. Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 15: Technical Data

    1) Value valid only for extension module. For an overall evaluation as per EN ISO 13849, a series connection to the respective basic module must be applied. = PFH + PFH Logic Basic Extension Tab. 6 Festo – GDCP-CMGA-E1-EN – 1404a...
  • Page 16 Internet: prohibited. Offenders will be liable for damages. All rights www.festo.com reserved in the event that a patent, utility model or design patent is registered. Original: de Version: 1404a Festo – GDCP-CMGA-E1-EN – 1404a...