– Setting the time
– Current values
– Holiday function
6
Select the day required for the heating phases (1 = Monday... 7 = Sunday/8 = dome-
4
stic hot water programme)
Start of phase 1: heating in set mode
5
End of phase 1: heating in reduced mode
6
Start of phase 2: heating inset mode
7
End of phase 2: heating in reduced mode
8
Start of phase 3: heating inset mode
9
End of phase 3: heating in reduced mode
10
Copying a day programme
1 1
Press this button to copy the current heating programme to the next day.
Press this button to copy the current heating programme to the previous
day.
The next day is displayed as confirmation.
To set the day of the week
12
(1 = Monday / 7 = Sunday).
Setting the hour.
13
Setting the minutes.
14
The setting of the time will change when a full hour is reached.
The current time is adjusted with
rate the adjustment.
Display and setting of the slope of the characteristic heating curve. Choose a gradient
15
indicated at point 2. 1 0.3 when the imposed room temperature is not reached.
Display of the current temperature in the boiler.
16
Display of the current burner power and operating mode (
17
domestic hot water)
For setting the number of days of absence.
18
The holiday symbol (
Monday / 7 = Sunday) and the number of holiday days on the right.
NOTE:
During the holiday period, the regulator will switch to availability mode.
When the set days have passed, the regulator will switch to automatic operation
mode.
The holiday function can be cancelled by pressing one of the operating mode buttons
and
keeping these buttons pressed will accele-
), will appear on the display, the start day on the left (1 =
= heating /
=