Physical Specifications; Performance Specifications - Emerson Rosemount 644 HART Reference Manual

Temperature transmitter, for product shipped before september 2012
Table of Contents

Advertisement

Reference Manual
00809-0100-4728, Rev MB
A.6.2 Physical specifications
Electrical connections
Model
Power and sensor terminals
Rosemount
Compression screws permanently fixed to terminal
644H
block
Field Communicator connections
Communication terminals
Rosemount
Clips permanently fixed to terminal block
644H
Materials of construction
Electronics housing and terminal block
Rosemount 644H
GE polyphenylene oxide glass reinforced
Enclosure (Options J5, J6)
Housing
Low-copper aluminum
Paint
Polyurethane
Cover O-ring
Buna-N
Materials of construction (stainless steel housing for
biotechnology, pharmaceutical industries, and sanitary
applications)
Housing and Standard Meter Cover
316 SST
Cover O-Ring
Buna-N
Mounting
The Rosemount 644H installs in a connection head or universal
head mounted directly on a sensor assembly, apart from a sensor
assembly using a universal head, or to a DIN rail using an optional
mounting clip.
Special mounting considerations
See
Figure A-5 on page 89
for the special hardware that is available
to:
Mount a Rosemount 644H to a DIN rail. (see
page
88)
Retrofit a new Rosemount 644H to replace an existing
Rosemount 644H Transmitter in an existing threaded sensor
connection head.(see
Table A-4 on page
98
Weight
Weight (stainless steel housing for Biotechnology,
Pharmaceutical Industries, and Sanitary Applications)
Enclosure ratings (Rosemount 644H)
All available enclosures are Type 4X, IP66, and IP68.
Sanitary housing surface
Surface finish is polished to 32 RMA. Laser etched product marking
on housing and standard covers.
A.6.3 Performance specifications
EMC (ElectroMagnetic Compatibility)
NAMUR NE 21 Standard
The Rosemount 644H HART meets the requirements for NAMUR
NE 21 Rating.
Figure A-4 on
95)
CE electromagnetic compatibility compliance testing
The Rosemount 644 is compliant with Directive 2004/108/EC.
Meets the criteria under IEC 61326:2006
Specifications and Reference Data
Code
Options
644H
HART, Head Mount Transmitter
F
Fieldbus,
OUNDATION
644H
Head Mount Transmitter
PROFIBUS PA
644H
Head Mount Transmitter
644R
HART, Rail Mount Transmitter
M5
LCD Display
J5, J6
Universal Head, Standard Cover
J5, J6
Universal Head, Meter Cover
J7, J8
SST Universal Head, Std. Cover
J7, J8
SST Universal Head, Meter Cover
Code
Standard cover
S1
840 g (27 oz)
S2
840 g (27 oz)
S3
840 g (27 oz)
S4
840 g (27 oz)
Susceptibility
Parameter
6 kV contact discharge
ESD
8 kV air discharge
Radiated
80 – 1000 MHz at 10 V/m AM
Burst
1 kV for I.O.
0.5 kV line–line
Surge
1 kV line–ground (I.O. tool)
Conducted
100 kHz to 80 MHz at 10 V
July 2016
Weight
95 g (3.39 oz)
92 g (3.25 oz)
92 g (3.25 oz)
174 g (6.14 oz)
35 g (1.34 oz)
577 g (20.35 oz)
667 g (23.53 oz)
1620 g (57.14 oz)
1730 g (61.02 oz)
Meter cover
995 g (32 oz)
995 g (32 oz)
995 g (32 oz)
995 g (32 oz)
Influence
HART
None
< 1.0%
None
None
< 1.0%
Specifications and Reference Data