Intel celeron n3350/pentium n4200- based fanless multifunctional computer with 7” widescreen capacitive touch lcd (18 pages)
Summary of Contents for Advantech HIT-W183
Page 1
User Manual HIT-W183 Healthcare Infotainment Terminal Computer...
Page 2
Note! A NOTE provides additional information intended to avoid inconve- niences during operation. Part No. 2008W18300 Edition 1 Printed in Taiwan June 2018 HIT-W183 User Manual...
Page 3
Repair of this equipment should only be conducted by trained service person- nel. Advantech recommends that a service contract be obtained with Advantech Service and that all repairs also be carried out by them. Otherwise, the correct functioning of the device may be compromised.
Page 4
Follow local regulations when disposing of the unit to ensure environmental pro- tection. Caution! When servicing the device, always use replacement parts that are quali- fied to Advantech standards. Advantech Medical cannot warrant or endorse the safe performance of third-party replacement parts for use with our medical devices.
Page 5
Warning! Do not modify the equipment with the authorization of the manufacturer. Warning! To avoid electric shock, the equipment must only be connected to a sup- ply mains with protective earthing. HIT-W183 User Manual...
Page 6
ISO 7000-0434: Caution, consult accompanying documents ISO 7000-1641: Follow the operating instructions or consult the instruc- tions for use IEC 60417 -5009: Standby IEC 60417-5032: Alternating current IEC 60417-5021: Equipotentiality ISO 7010-M002: Follow the instructions for use HIT-W183 User Manual...
Internet, send emails, request nurse assistance, and manage the ward environment, such as adjust the bed height, lighting, and curtains. The HIT-W183 healthcare infotainment terminal should not be used as a life-support system. The latest version of this user manual is available for download at http://support.advantech.com.tw/support/...
5 MP CMOS Smart card reader Internal USB Built-in module Second smart card reader Internal USB Optional built-in module Barcode scanner Internal USB Optional Handset module RJ12 Optional built-in SPK and Mic TV tuner (SMA jack) SMA jack Optional HIT-W183 User Manual...
1.3.3 Cleaning and Disinfecting During normal use of the HIT-w183 healthcare infotainment terminal, the device may become dirty and should be regularly cleaned. Steps Prepare pure water for cleaning. Moisten a cloth in the water and then wipe the HIT terminal.
Page 14
Mild reading vision impairment or vision corrected to log MAR 0,2 (6/10 or 20/ – Single-arm/hand system capable of guiding and holding a device – Average degree of aging-related short term memory impairment – Hearing impairment of 40% resulting in 60% hearing ability at 500 Hz ~ 2 kHz HIT-W183 User Manual...
Chapter System Setup This chapter describes the hard- ware features of the HIT-W183. Hardware Features Initial Setup BIOS Configuration Software Installation Driver Installation...
Before setting up the HIT-W183 terminal, take a moment to become familiar with the location and purpose of the controls, drives, connections, and ports (as illustrated in the figures below). The front panel of the HIT-W183 should appear as shown in Fig- ure 2.1.
(1) DC jack (2) Digital I/O phoenix port (4 pin) (3) USB 3.0 (4) Isolated RJ-45 LAN (5) VESA mount Figure 2.3 Underside view of HIT-W183 Figure 2.4 Button view of HIT-W183 Underside Buttons (1) Speaker (8) Reading light (2) Barcode scanner...
2.1.3 HIT-W183 with Handset (Optional) The HIT-W183 terminal can be equipped with an optional handset for bedside use. The handset (as shown in Figure 2.5) features two microphones and noise cancella- tion technology to eliminate environmental noise and ensure optimal sound quality.
Page 19
Open the cover to access the RJ12 connector. HIT-W183 User Manual...
Page 20
Use screws to attach the handset bracket via the screw holes provided. Replace the blue I/O cover with an I/O cover with handset hole. Tighten the screws to affix the cover in place. Then replace the rubber plugs. HIT-W183 User Manual...
Connect the 3-pin male plug of the power cord to an electrical outlet. Figure 2.6 Connecting the power cord Warning! The HIT-W183 terminal is compatible with a 63-watt power supply and requires a special adapter, as shown in Figure 2.6.
BIOS Configuration It is possible that the HIT-W183 terminal was setup and configured by your dealer prior to delivery. However, users may still need to access the BIOS setup program to adjust the system configuration data, such as the date and time or hard drive type.
Page 23
Guidance and manufacturer’s declaration – electromagnetic emissions The HIT-W183 terminal is intended for use in the electromagnetic environment specified below. Customers or users of HIT-W183 should ensure that the device is operated in such an environment. Electromagnetic environment – Emissions test...
Page 24
Guidance and manufacturer’s declaration – electromagnetic immunity The HIT-W183 terminal is intended for use in the electromagnetic environment specified below. Customers or users of the HIT-W183 terminal should ensure the device is operated in such an environment. IEC 60601 test...
Page 25
If the measured field strength in the location of where the HIT-W183 terminal is used exceeds the applicable RF compliance level specified above, the HIT-W183 terminal should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the HIT-W183 terminal.
You want to remove/install any parts Thermal Protection When using the HIT-W183 terminal, it is normal for the rear metal heatsink to become warm. The rear metal heatsink of the HIT-W183 terminal functions as a cooling sur- face that transfers heat from inside the device to the cooler external air. Do not block this heatsink with any soft material.
Never place anything on the system case before powering off the device. Never power on the device unless all of its internal and external parts are in place. Operating the terminal when it is open or missing parts is dangerous and may damage the equipment. HIT-W183 User Manual...
Watchdog API and Audio Path The HIT-W183 is equipped with a watchdog API and audio path to enable system integrators to conveniently control and protect the system. A.1.1 Watchdog A.1.1.1 Windows OS Users can setup the watchdog API and enable/disable the watchdog functions (including watchdog time, beeper on/off, and beeper time settings) via the HIT Series Java Library of the SDK.
Users can use the watchdog API to setup the watchdog and configure the following settings: A.1.2 Audio Path A.1.2.1 In Window OS The audio switch default setting is enabled. Users can enable/disable this function via the system settings. HIT-W183 User Manual...
Page 34
Users can turn the audio settings on/off via the audio path API in the HIT Series Java Library of the SDK. A.1.2.2 In Android OS The audio switch default setting is enabled. Users can enable/disable this function via the system settings. HIT-W183 User Manual...
If you require this service, please contact a service technician or your local retailer. Installation Instructions Attach the VESA mount bracket to the heat sink of the HIT-W183 terminal. Secure the bracket in place using four of the Philips-head screws provided. Mount the terminal onto the wall, stand, or desk mount.
Need help?
Do you have a question about the HIT-W183 and is the answer not in the manual?
Questions and answers