Data editing settings
Setting
No.
range
Sewing area limit in X direction [Units mm]
0 − 130
460
0 − 220
Sewing area limit in Y direction
461
0 − 100
Enlargement/reduction reference point
0
462
1
2
Enlargement/reduction for bar tacking
463
OFF
ON
Enlargement/reduction ratio in XY directions
OFF
464
ON
Storing parallel movement amount for sewing pattern
OFF
465
ON
Reading sewing data from eternal media into internal memory
0
1
466
2
Changing gear ratio correction method when reading from a 2DD floppy disk.
0
467
1
2
3
Retract point switching at parallel movement point
468
OFF
ON
Device settings
Setting
No.
range
Needle cooler device
550
OFF
ON
Tension release setting at the sewing start
551
OFF
ON
Tension release timing during thread trimming [Units 8 degree steps]
552
-10 − 1
Thread nipping timing (*5)
553
1 − 4
*5 Not used for the BAS-311G and BAS-326G.
BAS-311G setting value
BAS-326G setting value
[Units mm]
Center of sewing frame
Sewing start point
Center of pattern
Bar tacking stitches (pitch approx. 1 mm or less) cannot be enlarged or reduced.
Bar tacking stitches (pitch approx. 1 mm or less) are also enlarged or reduced.
Disabled
Enlargement/reduction ratio setting is the same for X and Y
(Disabled for user programs)
Initialized when program number or enlargement/reduction ratio is changed and
when power is turned off.
Initialized when program number or enlargement/reduction ratio is changed but not
when power is turned off.
[Normal mode] Programs are copied one by one into internal memory.
[Overwrite mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is deleted.
[Assignment mode] Sewing data is overwritten into the temporary buffer area.
If sewing data with the same program number already exists in internal memory, it
is not deleted, but only the data in the temporary buffer is used.
(If sewing data with the same program number already exists in internal memory
and the setting is changed to "0" or "1", the data in the temporary buffer will be
cleared.)
Automatic conversion as specified by sewing machine model.
(For the BAS-311G, data is read as BAS-311A data and then converted.)
BAS-311A data is read.
BAS-326A data is read.
BAS-341A/BAS-342A data is read.
Disabled
The position moved to by parallel movement is recorded as the retract point.
Disabled
Needle cooler device is used. (Option output No. 12)
Disabled
Enabled
-10: Early ← 0: Standard → 1: Late
1: Early ← 2: Standard → 4: Late
Setting items
Setting items
BAS-311G, BAS-326G
2. FUNCTION SETTINGS
Initial value
130
220
100
0
OFF
OFF
OFF
0
0
OFF
Initial value
OFF
OFF
0
2
11