9. TABLE OF ERROR CODES
Data editing-related errors
Code
The enlargement ratio setting caused the sewing data to extend outside the sewing area.
E500
Set the enlargement ratio again.
Sewing data that exceeds the sewing machine's sewing area was loaded.
E501
Check the size of the sewing data.
The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm.
E502
Set the enlargement ratio again.
Invalid code in sewing data.
E510
Reload the data from the CF card or floppy disk.
No end code has been input into sewing data.
E511
Input an end code, or change the program number.
Number of stitches exceeds allowed maximum.
E512
Extended option output number already exists. Change the extended option output number.
E520
If not using the extended option output, initialize the data to clear the extended option output data.
Changing program number is prohibited.
E530
Device-related errors
Code
Upper thread breakage occurred.
E600
Thread the upper thread. Resewing is then possible.
Thread nipper home position error.
Turn off the power, and then clean underneath the needle plate to remove any dust and thread scraps.
E690
Check that connector P10 on the main P.C. board is properly connected.
Thread nipper retract position error
Check if the upper thread trailing length is too long.
E691
Turn off the power, and then clean underneath the needle plate to remove any dust and thread scraps.
Check that connector P10 on the main P.C. board is properly connected.
P.C. board-related errors
Code
Abnormal rise in power supply voltage.
E700
Turn off the power and check the input voltage.
Abnormal rise in sewing machine motor drive voltage.
E701
Turn off the power, and then check the voltage.
Abnormal drop in power supply voltage.
E705
Turn off the power and check the input voltage.
Abnormal current detected in sewing machine motor.
E710
Turn off the power, and then check if there are any problems with the sewing machine.
Abnormal current detected in X-feed motor.
E711
Turn off the power, and then check if there are any problems in the X-feed direction.
Abnormal current detected in Y-feed motor.
E712
Turn off the power, and then check if there are any problems in the Y-feed direction.
Abnormal current detected in work clamp motor.
Turn off the power, and then check if there are any problems with the X-feed mechanism, Y-feed mechanism or
E713
work clamp lifter.
External error input (AIRSW) detected.
E730
Turn off the power, and then check the air pressure.
Cooling fan does not operate.
Turn off the power, and then check if the cooling fan is blocked with scraps of thread.
E740
Check that connector P22 on the main P.C. board is properly connected.
Check if the fuse (F6) is blown.
If an error code that is not listed above appears, contact the place of purchase.