1032 – AL Inj. Drift Limit 1 Cyl. A1
Cause
The drift correction for
energization (start and duration)
of injector A1 has violated limit 1.
The injector has soon reached its
maximum drift limit.
1033 – AL Inj. Drift Limit 1 Cyl. A2
Cause
The drift correction for
energization (start and duration)
of injector A2 has violated limit 1.
The injector has soon reached its
maximum drift limit.
1034 – AL Inj. Drift Limit 1 Cyl. A3
Cause
The drift correction for
energization (start and duration)
of injector A3 has violated limit 1.
The injector has soon reached its
maximum drift limit.
1035 – AL Inj. Drift Limit 1 Cyl. A4
Cause
The drift correction for
energization (start and duration)
of injector A4 has violated limit 1.
The injector has soon reached its
maximum drift limit.
1036 – AL Inj. Drift Limit 1 Cyl. A5
Cause
The drift correction for
energization (start and duration)
of injector A5 has violated limit 1.
The injector has soon reached its
maximum drift limit.
1037 – AL Inj. Drift Limit 1 Cyl. A6
Cause
The drift correction for
energization (start and duration)
of injector A6 has violated limit 1.
The injector has soon reached its
maximum drift limit.
Corrective action
u Schedule an injector replacement.
Corrective action
u Schedule an injector replacement.
Corrective action
u Schedule an injector replacement.
Corrective action
u Schedule an injector replacement.
Corrective action
u Schedule an injector replacement.
Corrective action
u Schedule an injector replacement.
MS15060/01E 2018-12 | Troubleshooting | 103