B. Object directories
Index
6206
Subindex 1 ... 6
Bit 0 ... 7
6207
Subindex 1 ... 6
Bit 0 ... 7
B-14
Note
With Index 6206 you can define the outputs which are to
assume the default status in the event of a fault.
With Index 6207 you can define the status which the fixed
outputs are to assume in the event of a fault.
The settings do not become active until the CPV valve ter-
minal is put into the operational mode. After each switch-
ing on or after each reset (hardware initialization, com-
munication initialization), the default values will automati-
cally be accepted, any maskings will be overwritten.
The following applies:
Definition
0 = status of the output is retained
1 = output assumes the status defined in Index 6207
0 = output is reset
1 = output is set
Festo P.BE-CPV-CO3-EN en 1201a