JUKI AMS-221F-2516 Instruction Manual page 66

Ip-500 operation panel
Table of Contents

Advertisement

No.
Name
Main motor XY feed synchronous
U101
control speed / pitch
With / without the intermediate presser
U103
control
U104 Intermediate presser lowering timing
Position of the intermediate presser /
U105
wiper operation
With / without the air pressure detec-
U108
tion
Setting of the lower position of inter-
U112
mediate presser
With / without the needle cooler con-
U129
trol
Count completion closing time (for
U145
VER. update)
Selection of unit for enlargement /
U170
reduction ratio
Reference point for enlargement /
U171
reduction
Number of stitches to be sewn before
U245
the grease runs out (higher-order 16
bits)
Offset at the position before cutting
U263
(outward)
Offset at the position before cutting
U264
(Inward)
Timing at which the thread trimmer
U314
waits and moves before thread trim-
ming at the beginning of sewing
Timing at which the thread trimmer
U315
trims the thread at the beginning of
sewing
Sewing specification for thread trim-
U316
ming at the beginning of sewing
Number of stitches to be sewn before
U319
thread is trimmed at the beginning of
sewing (stitches)
U320 Timing to start the air blower
Duration of operation of the air blower
U321
after thread trimming
Type of thread trimming (standard
U322
type, shorter-thread remaining type)
Selection item
0: 2800sti/min /3.5mm
1: 2200sti/min /3.5mm
2: 1800sti/min /3.5mm
3: 1300sti/min /3.5mm
0: Without (Fixed to lowering)
1: With (Lowering according to the
sewing data during operation)
2: With (Lowering regardless of for-
ward / backward travel of the feed )
0: Immediately before the start of
sewing machine head
1: Synchronized with the feeding
frame at the end
0: Wiper operates above the interme-
diate presser
1: Wiper operates above the inter-
mediate presser (at the lower end
position of intermediate presser)
2: Wiper operates under the interme-
diate presser
0: Without
1: With
0: Without
1: With
0: 0.01%
1: 0.1%
0: Reference point for enlargement /
reduction in VDT
1: 2nd origin
2: Mechanical origin
3: Sewing starting position
Number of counts increases on a
stitch-by-stitch basis
Clearing is only effective
0: S type (standard)
1: H type (heavy-weight materials)
2: G type (extra heavy-weight materi-
als)
0: Standard
1: Shorter-thread remaining type
– 63 –
Setting
Setting
Setting
range
rage
range
Meaning
Min
Max
0
0
3
1
0
2
0
0
1
1
0
2
1
0
1
3.5
0
7.0
1
0
1
0
0
99
1
0
1
0
0
3
0
0
0
0
-100
100
0
-100
100
0
-4
6
0
-4
6
0
0
2
2
2
4
0
-90
90
40
10
300
0
0
1
Unit &
-
-
-
-
-
0.1 mm
-
1 sec
-
-
-
1 pulse
1 pulse
1
1
-
1 stitch
1 mesc
-

Hide quick links: