3. INSTALLATION

3-1. Removing the bed fixing bolt

3-2. Adjusting the safety switch

– 3 –
Remove bed fixing bolt ❶ . This bolt is necessary
to transport the sewing machine.
In the case error 302 occurs when the sewing
machine runs after setup, remove screws ❶ (six
pieces) to detach the cover. Then, loosen the
safety switch mounting screw with a screwdriver
and move safety switch ❷ downward. In this
state, adjust the safety switch.