Control Panel

1
2
4
5
6
OPERATION
Figure 6
1. Ignition Light - When lit, indicates that pilot burner
has been ignited.
2. Ready Light - When lit, indicates steam generator
has reached 200º Fahrenheit (93º Celsius) and is
ready for the cooking cycle.
3. Cooking Light - When lit, indicates that a cooking
cycle is in progress.
4. Timed Cooking/Hold Mode - Set the cooking time
(0 to 60 minutes) - steam cooking will begin after the
door is closed. The cooking cycle will be interrupted
3
if the door is opened during the cooking cycle; re-
sume cooking by closing the door. Hold - For keeping
cooked foods warm after cooking, at or above 150°F
(65°C).
5. Main Power Switch
ON - The steam generator will automatically fill and
begin heating to the pre-set temperature for standby.
Red light will ignite on the main power switch.
OFF - The steam generator will drain. No lights.
DELIME - Closes the drain valve while TOTAL CON-
CEPT liquid is being poured into the steam generator
during the Delime procedure. Amber light will ignite
on the main power switch.
6. Temperature Display - Shows temperature within
the cooking cavity.
7. Buzzer - Signals end of cooking period (not shown).
CAUTION
Live steam and accumulated hot water in the
compartment may be released when the door
is opened.
Your steamer has been factory set when "ON" to maintain
water temperature during the "READY" phase at approxi-
mately 200° Fahrenheit (93° Celsius) just below water
boiling point. If the steamer is used at higher elevations
(above 2000 feet), a qualified technician should adjust the
"READY" phase temperature down to an appropriate tem-
perature, below the boiling point of water.