Run Automatic Measurements - Promax OD-590 User Manual

Digital oscilloscope
Hide thumbs Also See for OD-590:
Table of Contents

Advertisement

Available languages

Available languages

Vertical
Bandwidth:
Offset:
Coupling:
Scale:

6.1.2 Run automatic measurements.

Operation
Measure
Time Type
1.
Press the Measure key. F1 to F5 shows the result from the previous
measurement.
2.
Press any of F1~F5. The menu switches to edit mode.
3.
To select the first channel to be measured, press F1 repeatedly.
4.
To select the second channel to be measured, press F2 repeatedly
(essential for Delay measurement).
5.
To select the measurement type (Voltage, Time, and Delay), press F3
repeatedly.
6.
To select the measurement item, use the Variable knob. The
corresponding icon is shown on F4.
7.
To go back to the measurement result view, press F5.
01-2007
Full.
0.
Signal dependent
Signal dependent
Measurement
Result
Vpp
F 1
:
Vavf
F 2
:
Frequency
F 3
:
Dutycycle
F 4
:
RiseTime
F 5
:
Frequency, Period,
F 3
RiseTime, FallTime,
+Width, -Width,
Dutycycle
USER'S MANUAL. OD-590/91/92
Edit mode
(4CH) CH1/ 2/ 3/ 4
F 1
Source1
(2CH) CH1/ 2
(4CH) CH1/ 2/ 3/ 4
F 2
Source2
(2CH) CH1/ 2
Vpp, Vmax, Vmin,
F 3
Volt Type
Vamp, Vhi, Vlo,
Vavg, Vrms,
F 4
(Icon)
ROVShoot,
FOVShoot,
F 5
Back
RPREShoot,
FPREShoot
F 3
Delay Type
FRR, FRF, FFR,
FFF, LRR, LRF,
LFR, LFF
Page 66

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Od-591Od-592

Table of Contents