I/O SPECIFICATIONS

8.1
I/O Specifications
Connected to 24V DC service power supply
S/S
of PC
3.3kΩ
DOG
24V DC, 7 mA
3.3kΩ
STOP
24V DC, 7 mA
Connected to servo amplifier or external
PGO+
power supply
Response pulse width: 4 µs
PGO-
FX-1PG
FX
-1PG
2N
VH
24V ±10%, Current consumption: 15 mA
VL
5 to 15V, Current consumption: 20 mA
3.3kΩ
FP0
To pull-up resistor VH or VL
100k PPS pulse output, 5 to 24V DC, 20 mA or
FP
less
COM0
100k PPS pulse output, 5 to 24V DC, 20 mA or
RP
less
RP0
To pull-up resistor VH or VL
3.3kΩ
COM1
Output for clearing deviation counter
5 to 24V DC, 20 mA or less
CLR
Output pulse width: 20 ms
FX-1PG
(When home position return is completed or
limit switch is input)
I/O SPECIFICATIONS
Response lag: 1 ms
Response lag: 4 ms
from servo
amplifier or
external power
supply
3.3kΩ
3.3kΩ
FX
-1PG
2N
8
5 to 24V DC, Current consumption: 35 mA or less
(From servo amplifier or external power supply)
VIN
FP
100k PPS pulse output, 5 to 24V DC, 20 mA or less
COM0
RP
100k PPS pulse output, 5 to 24V DC, 20 mA or less
COM1
Output for clearing deviation counter
5 to 24V DC, 20 mA or less
CLR
Output pulse width: 20 ms
(When home position return is completed or
limit switch is input)