FX-1PG/FX
-1PG PULSE GENERATOR UNIT
2N
Multiplication of position data (b5, b4)
The position data HP, P(I),
b5
b4
Multiplication
P(II) and CP will be multiplied
0
0
0
10
by the value shown in the table
on the left.
1
0
1
10
2
1
0
10
3
1
1
10
Example: When the value of the set position P(I)
(BFMs #18 and #17) is 123 and the BFM
#3 (b5, b4) is (1, 1), the actual position (or
travel) becomes as follows:
123 × 10
3
Motor system of units
123 × 10
3
Machine system of units
Combined system of units
Pulse output format (b8)
The pulse output terminals FP and RP of the PGU
change as follows in accordance with the setting (0 or
1) of b8.
• When b8 = 0: Forward pulse (FP) and reverse pulse
(RP)
FP
Forward pulse
RP
Reverse pulse
FP (PLS)
RP (DIR)
= 123,000 (pulses)
= 123,000
-4
(µm,mdeg,10
inch)
= 123
-1
(mm,deg,10
inch)
OFF
ON
OFF
ON
BFM LIST
• When b8 = 1: Pulse (PLS) with
direction (DIR)
Forward
Reverse
Rotation direction (b9)
• When b9 = 0: The current position (CP) value
increases with a forward pulse (FP).
• When b9 = 1: The current position (CP) value
decreases with a forward pulse (FP).
This bit is used for the initial setting. The rotation
direction is not required to be changed in every
actual operation.
Home position return direction (b10)
• When b10 = 0: The current position (CP) value
decreases during return to the
home position.
• When b10 = 1: The current position (CP) value
increases during return to the home
position.
DOG input polarity (b12)
• When b12 = 0: The DOG (near point signal) input is
turned on when the workpiece is
coming near the home position.
• When b12 = 1: The DOG (near point signal) input is
turned off when the workpiece is
coming near the home position.
5
OFF
ON
OFF
ON
5-4