How the System Works

OVERVIEW: The cellulose insulation is loaded into the hopper. The agitator breaks-up and conditions
the insulation for proper density while also sweeping the insulation into the airlock. The airlock
transports the insulation into the airstream created by the blower system. Insulation is discharged
from the airlock into the hose. The insulation is further conditioned as it travels through the hose.
An introduction to key components of the system follows:
Electrical Panel: The electrical panel, combined with the
wired remote, provides operation of the machine.
Hopper: The hopper contains the insulation being fed into
the agitators.
Safety bars: Keep hands & foreign objects above the safety
bars at all times.
Agitators: The agitators condition the fibrous insulation.
The agitators provide high production rates and appropriate
insulation conditioning. The agitators also transport
insulation into the airlock.
Gate: The slide gate is between the agitators and the
airlock. The slide gate allows insulation to fall into the
airlock. The slide gate is opened fully during typical
Wired
operation. Close the gate slightly to increase the
Remote
conditioning of the insulation.
Airlock: The airlock transfers the insulation from the agitation system into the
airstream without coming into contact with the blower. Insulation is discharged
from the airlock into the hose.