Forcing Domestic Hot Water Production (Override); Modifying The Domestic Hot Water Set Point Temperatures; Monitoring The Energy Consumption - DeDietrich ALEZIO S V200 User Manual

Reversible air/water "split inverter" heat pump
Hide thumbs Also See for ALEZIO S V200:
Table of Contents

Advertisement

Fig.10
14 : 23
Zo...
Zone setup...
DHW1: DHW Schedule
Sunday
6:00
Comfort
55.0°C
Edit schedule entry
6:00
Comfort
55.0°C
Add time and Activity
Copy to other day
Set activity temperatures
5.10

Monitoring the energy consumption

Tab.20
Parameter
Cool Energy Consumpt
DHW Energy Consumed
CH Energy Consumed
7682822 - v03 - 27082018
3. Select the timer programme to be activated.
4. To modify the timer programme, select Zone configuration > DHW
Schedule.
5. Select the programme to be modified.
6. Select the day to be modified.
7. Carry out the following actions according to your needs:
MW-2000750-2
5.9.3
Regardless of the selected operating mode, you can force domestic hot
water protection to the comfort temperature (DHW comfort setpoint
parameter) for a defined duration.
1. Select the
Off
2. Select Hot water boost.
3. Define the duration in Hour and in Minute.
5.9.4
The production of domestic hot water operates with two set point
temperature parameters:
DHW comfort setpoint: used in the Scheduling, Manual and Hot water
boostmodes
DHW reduced setpoint: used in the Scheduling, Holiday and
Antifrostmodes
You can change these set point temperature settings to adapt them to
your needs.
1. Select the
Off
2. Select DHW comfort setpoint to modify this set point.
3. Select Zone configuration > Domestic Hot Water Setpoints > DHW
reduced setpoint to modify this set point.
If your installation is equipped with an energy meter, you can monitor your
energy consumption.
1. Select the
Description
Energy consumed for cooling
Enegy consumed for domestic hot water
Energy consumed for central heating
2. To reset the meters to zero, select Reset counters for the energy
consumption.
Information on the active timer programme is given in the upper part
of the screen.
The programmed activities for Sunday are displayed.
The last activity of the day remains active until the first activity of the
following day.
Modify the timings for programmed activities.
Add a new activity.
Delete a programmed activity (choose the activity "Delete").
Copy programmed daily activities to other days.
Modify temperatures linked to an activity.

Forcing domestic hot water production (override)

DHW tank icon.

Modifying the domestic hot water set point temperatures

DHW tank icon.
Air Src Heat pump icon.
23.5
The energy consumed since the last energy consumption meter
reset is displayed: