Forcing Domestic Hot Water Production (Override); Modifying The Domestic Hot Water Set Point Temperatures; Monitoring The Energy Consumption - DeDietrich ALEZIO S AWHP 4.5 MR User Manual

Reversible air/water heat pump
Hide thumbs Also See for ALEZIO S AWHP 4.5 MR:
Table of Contents

Advertisement

4 Operation
Fig.10
14 : 23
Zo...
Zone setup...
DHW1: DHW Schedule
Monday
6:00
Comfort
55.0°C
Edit schedule entry
Comfort
55.0°C
6:00
Add time and Activity
Copy to other day
Set activity temperatures
4.10

Monitoring the energy consumption

24
AWHP MIV-S
1. Select the
Off
Information on the current operating mode is given in the upper part
of the screen.
2. To activate the timer programming or to change the timer programme,
select Scheduling.
3. Select the timer programme to be activated.
Information on the active timer programme is given in the upper part
of the screen.
4. To modify the timer programme, select Zone configuration > DHW
Schedule.
5. Select the programme to be modified.
The programmed activities for Monday are displayed.
The last activity of the day remains active until the first activity of the
following day.
6. Select the day to be modified.
7. Carry out the following actions according to your needs:
Modify the timings for programmed activities.
Add a new activity.
MW-2000750-03
Delete a programmed activity (choose the activity "Delete").
Copy programmed daily activities to other days.
Modify temperatures linked to an activity.
4.9.3

Forcing domestic hot water production (override)

Regardless of the selected operating mode, you can force domestic hot
water protection to the comfort temperature (DHW comfort setpoint
parameter) for a defined duration.
1. Select the
Off
2. Select Hot water boost.
3. Define the duration in Hour and in Minute.
4.9.4

Modifying the domestic hot water set point temperatures

The production of domestic hot water operates with two set point
temperature parameters:
DHW comfort setpoint: used in the Scheduling, Manual and Hot water
boostmodes
DHW reduced setpoint: used in the Scheduling, Holiday and
Antifrostmodes
You can change these set point temperature settings to adapt them to
your needs.
1. Select the
Off
2. Select DHW comfort setpoint to modify this set point.
3. Select Zone configuration > Domestic Hot Water Setpoints > DHW
reduced setpoint to modify this set point.
If your installation is equipped with an energy meter, you can monitor your
energy consumption.
DHW tank icon.
DHW tank icon.
DHW tank icon.
7685690 - v04 - 06042020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents