5. Remove the keyboard and put it out of the front housing.
4.5.2
Attach the keyboard EXTA3-K*
Attach the keyboard
1. Remove the cover plate of the keyboard.
2. Replace the 8x distance bolts to 8x lock nuts. Tighten the lock nuts, torque 0,3 Nm.
3. Remove the connecting cabel of the keyboard. See chapter see chapter 4.5.
4. Place the keyboard from the front into the housing.See chapter see chapter 4.5 in reversed
order.
5. Put the connection rails from the back to the keyboard and mount it with the new enclosed
lock nuts. Tighten the lock nut of each rail as compact the keyboard can be moved. Adjust
the keyboard central. Tighten all lock nuts with suited tools, torque 0,4 Nm..
6. Attach the cable clamp. Depending on the version of the keyboard there are one or two
cables.
7. Attach the PE cable. Depending on the version of the keyboard there are one or two cables.
61