VisuNet EX2 GMP RM/PC 3700 Series
Installation and Commissioning
Which of these three concepts is used must be determined by the user on a case-to-case basis
(best interference suppression and safety).
Pepperl+Fuchs does not accept any responsibility for choosing the right shielding concept.
The "Box-A10" accessory provides a contact spring so that you can easily connect the cable
shield via a DIN mounting rail to earth.
Assembly instructions for EMC cable glands
1. Strip the cable and uncover the braiding.
2. Strip the braiding and isulation staircase style. With thin cables, the braiding can be folded
back over the insulation jacket.
3. Insert the cable into the gland until the braiding reaches the contact position.
4. Tighten the gland
5. Insert the cable through the union nut.
6. Insert the cable into the clamping insert and fold the braiding over the insert. The braiding
must overlap the O-ring by approx. 2 mm.
7. Fit the clamping insert into the intermediate gland.
8. Assemble the cable gland.
9. Cross section