Cable Gland Plate; Pin Assignment Receptacle For Wired Handheld Barcode Reader Pscan-D (At The Ex2 Mounting Bracket) (Com6)31 - Pepperl+Fuchs VisuNet EX2 GMP RM/PC 3700 Series Hardware Manual

Hide thumbs Also See for VisuNet EX2 GMP RM/PC 3700 Series:
Table of Contents

Advertisement

VisuNet EX2 GMP RM/PC 3700 Series
Product Specifications
2.8.2

Cable gland plate

3
1. M12 cable gland
2. M25 cable gland
3. Ground bolt
4. M16 cable gland
The following cable glands are mounted per default and are qualified for safe operation:
Size
M12
M16
M25
2.8.3
Pin assignment receptacle for wired handheld barcode reader PSCAN-D
(at the EX2 mounting bracket) (COM6)
Bottom view
Pins receptacle
1
2
3
4
5
2.8.4
Connecting base station PSCAN-B via connecting cable to VisuNet EX2
mounting bracket X5 (COM6)
Pull the connecting cable DATL-A4-0,50-3 through the suited cable gland of the cable gland
plate at the VisuNet EX2 mounting bracket.
4
1
2
4
1
Type
Fa Hummel 1.616.1600.50
Fa. Hummel 1.616.1600.50
Fa. Jacob 50.625 M/EX
Connection
layout
GND
Rx
Tx
US
GND
Suited cable diameter
3-6,5 mm
6-10 mm
11-16 mm
VisuNet EX2
Colors of the
Connection X5
enclosed cable
pin
brown
8
white
5
green
6
yellow
7
grey
8
VisuNet EX2
Connection X5
signal
GND
Rx
Tx
US
GND