Installation and Commissioning
Connecting Cable to VisuNet Ex2 GMP
Danger!
Danger of explosion
Substantial material damage, personal injury or even up to death
Before connecting or disconnecting the device must be disconnected from power supply.
The bigger, upper area of the EX2 mounting bracket is defined as Ex nA. Observe laws,
standards, and directives applicable to the intended use and the operating location. Observe
Directive 1999/92/EC in relation to hazardous areas.
1. If you use shielded cable, remove the cable sheat, trim the shielding braid back to 2 cm and
bring the cable shield into contact with the cable gland.
2. Pull the connection cables through the pedestal and thread them through the cable glands
(see table "Clamping Range in the Pedestal - Wrench Size" on page 50).