BREAKDOWN OF FIRING PATTERN CODE:
H
REPRESENTS THE NUMBER OF OUTPUTS USED, IN THIS CASE 8
(F =6, L = 12, ETC.)
4
REPRESENTS THE CYCLE TYPE OF THE ENGINE
2 = TWO-CYCLE
4 = FOUR-CYCLE
A
REPRESENTS THE ALTRONIC PATTERN CODE (SEE FORM CPU-95EVS AL)
360
REPRESENTS THE NUMBER OF GEAR TEETH OR HOLES TO BE SENSED
F
REPRESENTS A DESIGNATOR FOR CPU-95EVS VERSION 1
S
REPRESENTS THE CURRENT LOOP RETARD CURVE TYPE
A = 0° AT 4MA / 48° AT 20MA
B = 0° AT 4MA / 36° AT 20MA
C = 0° AT 4MA / 24° AT 20MA
D = 0° AT 4MA / 16° AT 20MA
E = 0° AT 4MA / 8° AT 20MA
N = SPECIAL NON-STANDARD TIMING CURVE VS. CURRENT OR RPM,
NON-FACTORY PROGRAMMED
S = SPECIAL NON-STANDARD TIMING CURVE VS. CURRENT OR RPM, FACTORY
PROGRAMMED
X = NO CURRENT LOOP CURVE
100
REPRESENTS THE SPECIAL VERSION NUMBER (ONLY EXISTS FOR TYPES N AND S)
#001
REPRESENTS THE SPECIAL FEATURE CODE
(TOTAL SUM OF ALL SELECTED OPTIONS; 001=DEFAULT)
064 = FORCE MULTI-STRIKE WHEN RPM IS LESS THAN 250
032 = FORCE MAX ENERGY WHEN RPM IS LESS THAN 250
016 = USE 1 STEP RETARD WHEN RPM IS LESS THAN 250
004 = FORCE MULTI-STRIKE WHEN MISC INPUT IS GROUNDED
002 = FORCE MAX ENERGY WHEN MISC INPUT IS GROUNDED
001 = USE 1 STEP RETARD WHEN MISC INPUT IS GROUNDED
CPU-95EVS OI 7-13
All rights reserved © ALTRONIC, LLC 2013
H4A360.FS100#001
9
NOTE: This number must be selected
and properly documented by the
originator.