6.2 The first mode selection can enable or disable the pre-configured retard curve
controlled by the 4-20 mA current loop input. The choices are ON or OFF, with
the active selection displayed in capital letters. A PC is required to configure the
4-20 mA curve; reference the programming instructions, form CPU-95EVS PI.
When the current loop is on, the current loop value is displayed (xx.x mA) with
the "A" capitalized. When the current loop is off, the value is displayed (xx.x ma)
with the lower case "a".
AT
TO
TO
TURN
TURN
ON
OFF
6.3 The next mode selection can enable or disable the pre-configured retard curve
controlled internally by engine RPM. To configure the RPM retard curve, reference
form CPU-95EVS PI.
AT THE
NEXT
OPTION
SCREEN
TO
TO
TURN
TURN
ON
OFF
CPU-95EVS OI 7-13
All rights reserved © ALTRONIC, LLC 2013
NOTE: DISPLAY
SHOWS CURRENT
LOOP ON.
FOR
TO
NEXT
EXIT
ESC
NEXT
OPTION
NOTE: DISPLAY
SHOWS RPM
MAP OFF.
FOR
TO
NEXT
EXIT
NEXT
ESC
OPTION