9.3 The next setup screen permits the operator to select one of three ignition spark
profile levels (E1,E2,E3) for the previously selected Single Strike or Multi Strike
mode.
Note 1: A special feature can be selected during configuration to use the maxi-
mum energy level below 250 rpm, or when the Misc Input is grounded.
This feature is not active in a standard configuration.
Note 2: The use of higher spark energy may tend to accelerate spark plug elec-
trode erosion.
Note 3: The energy levels are used to select preprogrammed spark profiles. Six
total, E1,E2,E3SS and E1,E2,E3MS. See Fig. 2 for spark profile details.