The VALUE PROTECTION can be password protected. The password
PROTECTION LOCK is enabled when programming options from the PC terminal
program. See the Programming Instructions, form CPU-95EVS PI for details.
When password protection is enabled the following menu appears instead of the
VALUE PROTECTION menu.
To enter the password press, use the function keys F1, F2, F3, F4 where F1=1,
F2=2, F3=3, F4=4 where the number entered is equal to the user assigned five
digit password. After the last digit of the proper password is entered, the VALUE
PROTECTION menu shown above will appear. If the password is not known, press
the ESC key to exit or the NEXT key to go on to the next setup menu.
9.7 The last setup screen permits the operator to enter an ignition test mode. This
test mode can fire all outputs cyclically, or individual outputs at a slow rate. This
feature can be used to troubleshoot primary wiring and Output Module operation.
Test mode will terminate if rotation of the engine is sensed. Diagnostic features
do not function while in test mode.
AT
PRESS FOR
TEST MODE
ENTER
THEN
BEFORE
STARTING
TEST MODE
PRESS TO
VERIFY
ENTER
PURGED
CPU-95EVS OI 7-13
All rights reserved © ALTRONIC, LLC 2013
PRESS
PRESS TO
NEXT
FOR NEXT
EXIT
OPTION
PRESS TO
NEXT
EXIT
NOTE: The password can be reset via
the terminal program provided with the
enhanced display. See form CPU-95EVS
PI for details.
NOTE: The Test-Mode is enabled by
the user during initial setup of display
module from PC terminal program. See
form CPU-95EVS PI for details.
ESC
WARNING: The operator MUST fully
purge the engine of combustible mix-
tures prior to selecting the test mode
operation. Pressing the enter key again
is a confirmation of this action.