4.8 The SHUTDOWN screen will supersede all other home displays if the logic level
shutdown input of the Ignition Module or the G-Lead of the output primary
connector is grounded or was previously grounded and the engine has not
stopped rotating. This screen indicates that the ignition is not firing because a
shutdown input was triggered to shutdown the engine. If a diagnostic fault or
warning exists while the ignition is in shutdown, a PRESS DIAG message will
appear on the display. The Fire Confirm Out switch will change state (switch
opens) and the other outputs will function as described above based on the
existence of faults or warnings.
4.9 From the HOME SCREEN, pressing the NEXT key allows you to cycle through the
configuration comments which describe the configuration of the ignition system.
AT
PRESS TO
NEXT
GO TO
NEXT
The configuration screens are shown starting on the next page.
CPU-95EVS OI 7-13
All rights reserved © ALTRONIC, LLC 2013
NOTE: Because EEPROMS can
be reconfigured (using a PC and
Altronic's configuration software),
these comments should be viewed to
identify and verify the configuration
settings of the ignition prior to
operation. Refer to the programming
instructions, form CPU-95EVS PI, for
further information on configuration.
6