[ CAN specs: ]
CAN interface connector : 9-pin D-sub male
CAN Baud Rate : 250k
Isolation Voltage : 3000 VDC power protection on CAN side, 2500Vrms
photo-couple isolation on CAN bus
Terminator Resistor: Selectable 120Ω terminator resistor by jumper
Specification; ISO-11898-2, CAN 2.0A and CAN 2.0B
[ Module specs: ]
Dimensions : 117mm x 72mm x 35mm (H x W x D)
Operating temperature : -25 to 75ºC (-13 to 167ºF)
Storage temperature : -40 to 80ºC (-40 to 176ºF)
Humidity : 5 to 95%, non-condensing
LEDs : PWR LED for power
J1939 LED for J1939 communication
MODBUS LED for Modbus communication
[ Software Utility Tool: ]
Provide Modbus network configuration interface.
Provide J1939 network configuration interface – Network Address /
Device Name, etc.
Provide J1939 Input / Output configuration interface.
[ Application: ]
Diesel power-train applications
In-Vehicle networks for trucks and buses
Truck-Trailer connections
Fleet management systems
On Board Diagnostics
Vehicle Automation
GW-7228 J1939/Modbus RTU Slave Gateway User's Manual (Ver 1.3, Apr/2011) ------------- 7