ICP DAS USA GW-7228 User Manual page 25

J1939/modbus rtu slave gateway
Hide thumbs Also See for GW-7228:
Table of Contents

Advertisement

J1939 Configuration
The J1939 network configuration parameters are described in Table
3-3 below.
Table 3-3 J1939 Configuration Parameters
Item
Network
It shows the current location of J1939
Address
network.
To be used by the module in address claim
Device
messages, each J1939 module should have
NAME
a unique NAME.
Auto CAN
When Can Bus-off, the module will auto
Bus-Off
reset the CAN controller.
Reset
PDU1 Check
Enable/Disable to check the destination
Destination
address in PDU1 mode.
Address
If this option is enabled, data in the I/O table
Swap IO
would
Byte
boundaries; this function is easy reading the
J1939 data on Modbus network.
Enable or Disable auto transmission J1939
Auto
output message without to control the
Transmission
Modbus register 42009 (Dec).
Network
This is the list of possible addresses, the
Address
module only claims a single address at a
Configuration
time. Up to 20 addresses may be in this list.
GW-7228 J1939/Modbus RTU Slave Gateway User's Manual (Ver 1.3, Apr/2011) ------------- 25
Description
be
byte
swapped
Range
0~254
Please see
the
J1939-81
specification
Enable
Disable
Enable
Disable
on
16-bit
Enable
Disable
Enable
Disable
0~253