Custom Manual programs can be used for many specialized functions that are commonly started
from the controller, to save tedious setup each time the function is needed. They also permit very
flexible programming for unusual applications.
To create a Custom Manual program: Press the Information button, and turn the dial the Manual
Operations position. The Custom Manual setup screen will appear.
The screen will show a setup form for Custom Manual Prg 01.
To set up a different Custom Manual, press the Programs button to advance.
To continue setting up the selected Custom Manual, press the down arrow to advance to the first
Event.
Events can be stations, SSGs, or even Delays. Events are the order in which items will run.
Use the + or – button to choose a station or SSG for the first event.
Use the right arrow to move to the duration (time) for the event. This can be completely different
from any run times that item may have in regular programs (A-F).
Use the down arrow to move to the next event, and continue until the Custom Manual program is
complete.
Custom Manual rules:
Delays can be inserted as Events. Use the + or – buttons (the – button is often closer) to scroll
through the stations and SSGs to DELAY (occurs below Station 01, and above the highest
numbered station or SSG). Set a time for the delay as though it were a station.
Stations and SSGs may be mixed in a Custom Manual.
The same station (or SSG) may be included multiple times in a Custom Manual.
Stations (or SSGs) may run in any order in Custom Manuals, unlike automatic programs.
Custom Manuals are always run in an overlapping mode, because they are manually started.

To start a Custom Manual:

• Turn the dial to the Manual Operation position.
• Use the Program button to select the Custom Manual program (Custom Manual programs
will appear after the A through F selections).
• Turn the dial to Run, to start the Program at the beginning. The display will show "To
Manually Start Station 01...", but this only indicates that it will start at the beginning of
the program. Each station will run for its programmed time (including Cycle and Soak
settings), and stations with no run time in the selected program will be skipped.
• To start later in the Program (at a higher numbered station), use the down arrow to move
to the station number, and press the +/- buttons to advance to the desired station (or SSG)
number.
• Turn the dial back to Run to start the Program at the desired station. The Program will
begin at that station and continue until the last event, then stop.
The display will show #-CUST under Mode, to show why the stations are running.

Test Program: Programs button (hold)

ACC has a quick Test program which will run all stations for a selectable period of time, in
numerical order. The Test is an easy way to walk through every station in the system to verify