ACC2
CONTROLLER PROGRAMMING INSTRUCTIONS
SD
PROGRAMS
STATIONS
Start Times
Station Setup
Run Times
Cycle & Soak
Water Days
Blocks
Seasonal Adjust
Station Limits
Program Rules
Station Summary
Calendar Days Off
Program Summary
SETTING TIME AND DATE
Dial to Settings menu and select Time/Date.
(Select Regional Settings to customize time and date formats.)
Select current time, rotate dial to set.
Select current date, rotate dial to set.
PROGRAMMING
From Home, press Main Menu, and dial to Programs menu.
Start times
Select Start Times from Programs menu.
Select Program number. Up to 32 Programs are possible.
Programs may be named by selecting Name box.
Set Mode to Auto for automatic operation.
Check Overlap to allow the program to run at the same time
as other programs.
Check Stack if the program must only run by itself.
Select Start Time boxes, and rotate dial to set Start Time.
Run Times
Select Run Times from Programs menu or shortcut key.
Verify or select program number.
Run Type may be Station or Block (dial to select).
Blocks are groups of stations that run together, see manual.
Select and set Station (or Block) number.
Stations or Blocks will run in the order they are entered.
Select and set Run Time in HH:MM (hours/minutes). Select
:SS seconds, if desired.
Show Edit Tools (soft key) for shortcuts.
"Fill Down" (soft key) will add one number to previous station
on next line, and copy run times to it.
"Adjusted Run Time" shows effects of Seasonal Adjust, if
other than 100%.
Power Module Connections
OPERATING THE CONTROLS
Dial scrolls through menus, press dial in to select.
Back button returns to last screen.
Home button always returns to Home (Activity) screen.
Soft keys are labeled in each screen for different functions.
From Home, "Main Menu" soft key goes to all programming menus.
Built-in SD card reader can store logs and update the modules.
DEVICES
FLOW
P/MV Operation
Flow Operations
Flow Sensors
MainSafe
Solar Sync
Flow Zones
Clik Sensors
Flow Totals
Sensor Response
Learn Flow
Clear Flow Alarms
Hydraulic Summary
Water Days
Select Water Days from Programs menu or shortcut key.
Verify or select Program number.
Mode: Select Day of Week, Odd/Even dates, Interval, or
Manual Only. Manual Only will not run automatically.
Check the Days of the Week to water, or check Odd or Even,
or set Interval period. If Interval, specify start date of interval.
(Non-Water Days never water, even if the schedule happens
to fall on them.)
SET PUMP/MASTER VALVE OPERATION
Turn dial to Devices menu, and select P/MV operation.
Verify or select P/MV number.
Set Normally Closed or Normally Open operation.
Exit (Back button) and dial to Stations menu.
Select Station Setup.
Check boxes for the P/MV assignments for each station.
MANUAL OPERATIONS
From Home screen, press Manual soft key.
Use soft keys to select Stations, Program, or Test Program.
Stations: Check Sequential or Simultaneous.
Enter Stations or Blocks. Enter Run Times for each.
Press soft key for Start to run the items immediately.
Programs: Select Program number.
Press Start soft key to start immediately.
Or, dial to advance to a station further in the program, and
press Start to begin there.
Test Program: Test will run all stations in the controller for
the run time entered here.
SETTINGS
DIAGNOSTICS
Time/Date
View Logs
Regional Settings
Module Info
User Management
Clik Sensor Diagnostics
Networking
Station-P/MV Diagnostics
Flow Sensor Diagnostics
Solar Sync Diagnostics
SENSOR BYPASS
Active sensors do not interfere with manual irrigation.
If sensor is active and preventing desired automatic
irrigation, the sensor can be disabled temporarily.
Dial to Devices menu.
Select Clik Sensors or Solar Sync, depending on which type
has caused the alarm.
Select the sensor, and uncheck the Enable (Clik Sensor or
Solar Sync) box.
Check Enable again to restore sensor to normal operation.
MESSAGES & ALARMS !
The flashing
Press View Messages to read them.
Press View Logs for a detailed view of all alarms and
messages, beginning with the most recent. Use the dial to
review recent activity.
Press Clear Messages to return to the Home/Activity screen.
Messages do not interrupt automatic irrigation, but they
may announce a condition that does.
VIEW FLOW
When flow sensors are installed and configured, View Flow
will show current flow rate of all sensors.
Clear Messages to show the View Flow key again.
More detailed information is available on the Flow menu.
Select Flow Totals.
Consult product manual for Flow Operations & Advanced
Features.
POWER SUPPLY BOARD
Facepack Connection
SyncPort™
Service Screws
ADVANCED FEATURES
Export Logs
Easy Retrieve
Reset Memory
Firmware Update
Conditional Response
symbol shows that problems are detected.
!