However, if an automatic Program (A-F) was started Manually, it will be shut down by an active
sensor that is configured to shut down that program.
The sample display on the right shows a single active sensor alarm in process, with a range of
possible responses. The operator has pressed the + button after the FAULT display, to view
controller status.
Station 02 was running in Program A, and that Program has been Suspended (the seconds timer
would still be counting, but watering would be stopped).
Station 06 was running in Program B, and has been Paused. The seconds timer would be frozen
(and watering would be stopped).
Station 05 was running in a Custom Manual program, and the sensor would have no effect on it.
Station 05 would still be watering in Custom Manual 1.
There is no direct Override for a Clik sensor. Depending on what needs to be accomplished, the
Test program is still available (for winterization functions) and individual stations can still be
started from the Manual position.
If a sensor is alarmed, and a Manual Program start is attempted for a Program with a response for
that sensor, the display will show "CANNOT RUN MANUAL. A sensor is active for this
program." That program cannot be manually started until the sensor is reset.
If full operations must be restored when a sensor is in alarm, turn the dial to the Set Sensor
Operation position, and use +/- to change the sensor response to Off (by program).
View recent alarms, or alarm history, by turning the dial to the Data History position and
selecting Alarm Logs (see Data History).

Setting Program Overlap Options

There are three program overlap options. These options allow you to maximize the number of
stations operating simultaneously, if the system's hydraulics can support the flow.
To program the Program Overlap option:
• Turn the dial to the SET PROGRAM OVERLAP OPTIONS position
• Use the Up and Down buttons to navigate to changeable portions of each display.
• Use the +/- buttons to see and set the choices.
Once the Program Overlap Option has been selected for the controller, individual programs can
be set to Overlap or Stack at the Set Program Start Times position.

Option One: Stack or Overlap