Set the locking lever to engage positively when applied. This is done by pulling the lever towards you whilst
at the same time winding in the screw with an appropriate screwdriver. When at top dead centre, the lever
should start to engage to lock the reaction post's position. Turn the lever to the right and you should start to
feel some resistance as the lock is engaged. Before continuing check the reaction post assembly is securely
fixed in position.
FIGURE 13 – Adjusting and Setting the Locking Lever

8. Mount Transducer (not supplied with TWC)

Select the correct capacity transducer and secure to the platform.
FMT Transducer
Directly mount with 3 fixings. Torque settings are 25 N·m for 400 and 85 N·m for 1500.
FIGURE 14 – Fitting an FMT Transducer
To save time when using multiple FMT transducers use the optional FMT quick release kit (Part number
60322) first (see page 75).
Static Transducer
Use optional static transducer kit ((Part number 60318) see page 73).
Place static transducer male square into the TWC.
Use optional adaptors (Part number 29214, 29215, 29216, 29217) as
required (see page 73); to reduce uncertainties these adaptors have been
manufactured to close fit tolerances.
Place support over transducer and secure to TWC with socket cap screws
provided.