TTT SERIES 3 OPERATORS HANDBOOK
INTRODUCTION:- ____________________________________________________________
The 3 transducer connectors are designed for use with most four wire bridge strain gauge type
transducers.
When used with Norbar 'SMART' transducers the calibration data will be automatically known.
For 'NON-SMART' transducers up to 20 sets of transducer parameters can be stored in the TTT
for ease of use. These can be configured with USER units.
TIP. Mark 'NON-SMART' transducers with their stored 'T' number for ease of identification.
Ensure transducer selection switch is in the correct position for the transducer in use. See the
TD#1, TD#2 & TD#3 symbols next to transducer connectors.
TIP. Press '#' in track mode to show details of transducer in use.
TIP. If any of the transducer's parameters are changed i.e. re-calibration of mV/V value, the
transducer's stored parameters must be edited prior to use. ('NON-SMART' only).
Norbar transducers with the following suffix are all suitable for use with the TTT:
Suffix
Description
XXXXX.IND
'SMART' transducer calibrated in mV/V.
XXXXX.INDA
'SMART' transducer with integral angle encoder calibrated in mV/V.
XXXXX.LOG
'SMART' transducer calibrated with a TTT in units of calibration.
A mV/V figure is also supplied.
XXXXX.LOGA
'SMART' transducer with integral angle encoder calibrated with a TTT in
units of calibration. A mV/V figure is also supplied.
NOTE: - Transducers supplied for use with the Pro-Log are compatible with the TTT.
The TTT will not display angle when interfaced to a .INDA or .LOGA transducer.
ETS Transducers supplied with an amplifier module will need to be modified for use
with the TTT.
TRANSDUCER LEADS AVAILABLE:-_____________________________________________
Part Number
60216.200
60217.200
60223.200
NOTE: - The suffix after the part number indicates the length of the lead in cm, thus
XXXXX.200 = 2 metres. If Transducer leads are required of a non-standard length, the
new suffix must be added to the part number when ordering (to the nearest metre).

TRANSDUCER INTERFACE

Description
TTT to 10 way lead, for Norbar Rotary Transducers.
TTT to 6 way lead, for Norbar Static & Annular Transducers.
TTT to no connector (for non-Norbar transducers).
PAGE 18 OF 28